Recording System Check - Sony DCR-PC10 Service Manual

Digital video camera recorder
Hide thumbs Also See for DCR-PC10:
Table of Contents

Advertisement

4-2. Recording System Check

Note: Perform "Playback System Check" before this check.
(Playback the BIST check tape.)
Mode
VTR playback, CAMERA REC
Signal
BIST signal
(Alignment tape XH5-6: NTSC)
(Alignment tape XH5-6P: PAL)
Measurement Point
Adjusting remote commander
Measuring Instrument
Adjustment Page
3, 4
Adjustment Address
14, 15, 16, 17, 18, 19, 1A, 1B
Specified Value
Shown in the following check
procedures respectively
Check procedure:
Order
Page
Address
1
2
4
41
3
4
0F
4
4
0E
5
4
40
6
4
0F
7
4
40
8
4
40
9
4
0F
10
4
40
11
4
40
12
4
0F
13
4
40
14
15
16
17
4
11
18
4
42
19
4
13
20
4
42
21
4
11
22
4
17
16
23
3
01
24
4
1C
25
4
11
26
4
11
27
4
13
28
4
15
14
Data
Playback the alignment tape (XH5-6: NTSC, XH5-6P: PAL) in VTR mode.
01
After setting the data, press the PAUSE button.
02
After setting the data, press the PAUSE button.
01
After setting the data, press the PAUSE button.
01
After setting the data, press the PAUSE button.
0A
After setting the data, press the PAUSE button.
00
After setting the data, press the PAUSE button.
01
After setting the data, press the PAUSE button.
0E
After setting the data, press the PAUSE button.
00
After setting the data, press the PAUSE button.
01
After setting the data, press the PAUSE button.
8E
After setting the data, press the PAUSE button.
00
After setting the data, press the PAUSE button.
While depressing the HOLD switch of the adjustment remote commander to ON (The
service LANC mode), eject the alignment tape then insert the recording tape instead.
While depressing the HOLD switch of the adjustment remote commander to ON (The
service LANC mode), move the POWER switch from VIDEO side to the CAMERA side.
Move the CAMERA REC STANDBY to the CAMERA RECORD position.
08
After setting the data, press the PAUSE button.
01
After setting the data, press the PAUSE button.
07
After setting the data, press the PAUSE button. Data returns automatically to 00.
00
After setting the data, press the PAUSE button.
00
After setting the data, press the PAUSE button.
When the IC1500 (U1)
displayed in page: 4, address: 16 and 17.
Address
NTSC model
17
16
0D
After setting the data, press the PAUSE button.
FF
After setting the data, press the PAUSE button.
04
After setting the data, press the PAUSE button.
00
After setting the data, press the PAUSE button.
03
After setting the data, press the PAUSE button. Data returns automatically to 00.
When the IC1503 (T1)
displayed in page: 4, address: 14 and 15.
Address
NTSC model
15
14
Procedure
IC1503 (T1) playback system is normal, following data will be
PAL model
C6
F8
90
3E
IC1701 (D1) playback system is normal, following data will be
PAL model
C6
F8
90
3E
5-58