4. Backlight Consumption Current Adjustment

(VC-240/241 board)

Set the backlight luminance and color temperature.
If deviated, the image may become dark or bright.
Mode
Camera
Subject
Arbitrary
Measurement Point
+ Probe: Pin 2 of CN009 (EVF BL+)
Probe: Pin 3 of CN009 (EVF BL )
Measuring Instrument
Digital voltmeter
Adjustment Page
D
Adjustment Address
9C, 9D, 9E
Specified Value
DCR-TRV20/TRV20E:
BRIGHT mode : A=25.0 ± 1.5mVdc
NORMAL mode : A=15.0 ± 1.5mVdc
DCR-TRV6/TRV6E/TRV11/TRV11E:
BRIGHT mode : A=17.0 ± 1.5mVdc
NORMAL mode : A=10.0 ± 1.5mVdc
Note1: Perform the adjustment in the following order.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 9C to 9F, and set the data to the initial
value.
Note: To write in the non-volatile memory (EEPROM), press the
PAUSE button of the adjustment remote commander each time
to set the data.
Address
9C
Data
E0
3)
Select page: D, address: 9D, change the data and set the voltage
difference (A) between Pin 2 of CN009 (EVF BL+) and Pin
3 of CN009 (EVF BL ) to the specified value of BRIGHT
mode.
(The data of address: 9D should be "C0" to "FF".)
Note: The backlight consumption current adjustment BRIGHT mode
is set up automatically.
4)
Press the PAUSE button of the adjustment remote commander.
5)
Select page: D, address: 9C, set the same data as page: D,
address: 9D, and press the PAUSE button.
6)
Select page: D, address: 9E, change the data and set the voltage
difference (A) between Pin 2 and Pin 3 to the specified value
of NORMAL mode.
(The data of address: 9E should be "00" to "1F".)
Note: The backlight consumption current adjustment NORMAL mode
is set up automatically.
7)
Press the PAUSE button.
8)
Select page: 0, address: 01, and set data: 00.
9D
9E
9F
E0
11
1F

5. White Balance Adjustment (VC-240/241 board)

Correct the white balance.
If deviated, the reproduction of the EVF screen may degenerate.
Mode
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Note: Check the white balance only when replacing the following parts. If
necessary, adjust them.
1. LCD panel
2. Light induction plate
3. IC1802
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 97 and 98, set the data to the initial
value.
Note: To write in the non-volatile memory (EEPROM), press the
PAUSE button of the adjustment remote commander each time
to set the data.
Address
Data
3)
Check that the EVF screen is not colored. If colored, change
the data of page: D, address: 97 and 98 so that the EVF screen
is not colored.
Note: To write in the non-volatile memory (EEPROM), press the
PAUSE button of the adjustment remote commander each time
to set the data.
When address: 97 or 98 is selected, the white balance
adjustment mode is set up automatically.
4)
Select page: 0, address: 01, and set data: 00.
5-35
Camera
Arbitrary
Check on EVF screen
D
97, 98
The EVF screen should not be colored.
97
98
80
80

Hide quick links: