1-5.

LCD SYSTEM ADJUSTMENT

Note 1: The back light (fluorescent tube) is driven by a high voltage AC
power supply. Therefore, do not touch the back light holder to
avoid electrical shock.
Note 2: When replacing the LCD unit, be careful to prevent damages
caused by static electricity.
Note 3: Set the LCD BRIGHT to the center.
Set the LCD COLOR (Menu display) to the center.
Note 4: PD-123 board: DCR-TRV11/TRV11E/TRV20
PD-124 board: DCR-TRV6/TRV6E/TRV20E
VC-240 board: DCR-TRV20/TRV20E
VC-241 board: DCR-TRV6/TRV6E/TRV11/TRV11E
[Adjusting connector]
Most of the measuring points for adjusting the LCD system are
concentrated in CN009 of the VC-240/241 board.
Connect the Measuring Instruments via the CPC-8 jig (J-6082-388-
A).
The following table shows the Pin No. and signal name of CN009.
Pin No.
Signal Name
1
LANC SIG
3
EVF BL –
5
EVF VCO
7
PANEL VG
9
H START
11
PANEL COM
13
TCK
15
JIG TDO
17
SWP
19
GND
Table. 5-1-13.
CN009
1
2
19
20
Remove the CPC lid
Fig. 5-1-17.
Pin No.
Signal Name
2
EVF BL +
4
EVF VG
6
GND
8
PD VCO
10
XHD/PSIG
12
TMS
14
JIG TDI
16
GND
18
RF IN/LANC JACK IN
20
RF MON
1-5-1.
LCD SYSTEM ADJUSTMENT

(DCR-TRV11/TRV11E/TRV20)

1. VCO Adjustment (PD-123 board)

Set the VCO free-run frequency. If deviated, the LCD screen will
be blurred.
Mode
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Note: NTSC: DCR-TRV11/TRV20
PAL: DCR-TRV11E
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: A2, change the data and set the VCO
frequency (f) to the specified value.
Note: The VCO adjustment mode is set up automatically, so the LCD
screen falls into the disorder.
3) Press the PAUSE button of the adjustment remote commander.
4) Select page: D, address: A3, set the same data as page: D,
address: A2, and press the PAUSE button.
5) Select page: 0, address: 01, and set data: 00.
5-36
Camera
Arbitrary
Pin 9 of CN009 (H START) of
VC-240/241 board
Frequency counter
D
A2, A3
f = 15734 ± 30Hz (NTSC)
f = 15625 ± 30Hz (PAL)