Recording System Check; Preparations For Recording; Ic301 Trx (Rf) Rec Bist Check; Processing After Completing Recording System Check - Sony DCR-VX2000 Service Manual

Digital video camera recorder
Hide thumbs Also See for DCR-VX2000:
Table of Contents

Advertisement

2. Recording System Check

2-1. Preparations for recording

Order Page Address Data
1
2
3
10
C0
3
3
11
07
4
5
6
7
8
3
01
0C

2-2. IC301 TRX (RF) REC BIST Check

Order Page Address Data
1
3
70
04
2
3
70
00
3
3
71
4
3
72
5
3
Procedure
Playback the BIST check tape.
(XH5-6(NTSC), XH5-6P(PAL))
Set the data, and press PAUSE
button.
Set the data, and press PAUSE
button.
Enter the stop mode.
While keep the HOLD switch of
the adjustment remote
commander at ON (SERVICE)
position, eject the BIST check
tape.
Close the cassette compartment
without inserting a cassette.
Set the power switch to
"CAMERA".
Set the data, and press PAUSE
button.
Procedure
Set the data, and press PAUSE
button.
Set the data, and press PAUSE
button.
Check that the data is equal to
either of the following values.
And memorize the case number
of the value.
NTSC model:
26 (Case1), 5E (Case2)
PAL model:
53 (Case1), 77 (Case2)
Check that the data is equal to
the following value which case
number is equal to that of
address 71.
NTSC model:
95 (Case1), E3 (Case2)
PAL model:
DF (Case1), D5 (Case2)
If the data of address 71 and
address 72 are correct, IC301
TRX (RF) recording system is
normal.
2-3. Processing after Completing Recording System
Check
Order Page Address Data
1
3
01
2
5-54
Procedure
00
Set the data, and press PAUSE
button.
Turn off the power and turn on
again.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dcr-vx2000e

Table of Contents