page 34
15
Check the primary circulation pump for
corrosion or scale.
Is there
corrosion or scale inside the primary
circulation pump?
Check the following elements for soiling and/
or damage:
- the combustion-air inlet conduit
- the air suction tube,
- the gas orifice, see page 101
- the blower, see page 86
- the connection between the blower and the
burner
- the burner
- the heat exchanger, see page 117
- the flue gas conduit.
Are the above-
mentioned components clean and
free from damage?
Measure the inlet gas pressure (flow
pressure). See page 107.
Is the inlet gas pressure
okay?
16
page 40
Logamax plus GB142-24/30/45/60 - We reserve the right to make any changes due to technical modifications!
Yes
No
No
Yes
No
Yes
Clean the primary
circulation pump (inside).
Clean and/or replace the corresponding
components.
If the required inlet gas pressure is not
available, you should consult the relevant
gas utility company.
Diagnosis
8
page 31
7
39