8
Actions
Remove both cable plugs from the fan unit (see fig. 43, pos. 1).
Loosen the union nut of the gas control valve (see fig. 44,
pos. 1).
Loosen both sets of retaining clips (fig. 44, pos. 2 and fig. 45,
pos. 1) of the burner cover and remove the burner cover with
the fan unit and the gas burner fitting.
102
Logamax plus GB142-24/30/45/60 - We reserve the right to make any changes due to technical modifications!
1
fig. 43
Disconnect the cable plug from the fan unit
1
fig. 44
Loosening the union nut
1
fig. 45
Loosening the retaining clips
2
1