8
Actions
Loosen the union nut of the gas control valve (see fig. 76,
pos. 1).
Loosen both sets of retaining clips (fig. 76, pos. 2 and fig. 77,
pos. 1) of the burner cover and remove the burner cover with
the fan unit and the gas burner fitting.
Remove the burner gasket (see fig. 78, pos. 1).
Remove the gas/air distributor plate (see fig. 78, pos. 2).
Remove the orifice plate (only applies to Logamax plus
GB142-24/30 and GB142-60) (see fig. 78, pos. 3). Note that
the orifice plate of the GB142-60 has a different shape.
Remove the burner (see fig. 78, pos. 4).
114
Logamax plus GB142-24/30/45/60 - We reserve the right to make any changes due to technical modifications!
1
fig. 76
Loosening the gas control valve
1
fig. 77
Loosening the retaining clips
fig. 78
Removing the burner
2
1
1
2
3
4