Specifications

Physical Characteristics

For two-dimensional drawings and three-dimensional models of the C Series
Note
module and connectors, visit
Safety
NI 951x User Manual
Thermal dissipation (at 70 °C)
Active mode.....................................1.5 W max
Sleep mode ......................................0.4 mW max
V
input ................................................19 to 30 V
sup
NI 9512............................................375 mA max
NI 9514............................................150 mA max
NI 9516............................................150 mA max
+5 V regulated output .............................5 V ±5%
NI 9512............................................150 mA max
NI 9514............................................150 mA max
NI 9516............................................300 mA max
If you need to clean the module, wipe it with a dry towel.
ni.com/dimensions
Weight ....................................................155 g (5.5 oz)

Safety Voltages

Connect only voltages that are within the following limits.
Channel-to-COM ....................................0 to +30 VDC max,
Isolation
Channel-to-channel..........................None
Channel-to-earth ground
Continuous ...............................60 VDC,
Withstand .................................500 V
and search by module number.
Measurement Category I
Measurement Category I
dielectric withstand test
A-6
, verified by a 5 s
rms
ni.com