4.5 Basic Setting Commands
YS?
Query
Example
Set the address to 2, the baud rate to 9600, the
data length to 8, the parity check to ODD, and
the NORMAL protocol.
YS 2,9600,8,ODD,NORMAL
Description • The settings specified by this command and
saved using the XE command take effect after
the recorder is power cycled.
• If p5 is set to MODBUS, Modbus slave is
selected.
XQ
Sets the TLOG timer
(/M1 option).
When not using the timer
Syntax
XQ p1,p2<terminator>
p1 Timer number (1 or 2)
p2 Timer type (OFF)
XQ[ p1]?
Query
Example
Disable the number 1 timer.
XQ 1,OFF
When using an absolute timer
XQ p1,p2,p3,p4,p5,p6<terminator>
Syntax
p1 Timer number (1 or 2)
p2 Timer type (ABSOLUTE)
p3 Interval (10min, 12min, 15min, 20min,
30min, 1h, 2h, 3h, 4h, 6h, 8h, 12h, 24h)
p4 Reference time (fixed to HH format)
HH
p5 Reset/not reset the data when the timer
expires (ON/OFF)
p6 Printout ON/OFF (ON, OFF)
XQ[ p1]?
Query
Example
Set an absolute timer to timer number 1. Set the
interval to 30 minutes, the reference time to hour
7, reset the data when the timer expires, and
disable printout.
XQ 1,ABSOLUTE,30min,07,ON,OFF
Description Each time the interval specified by p3 elapses
from the time specified by p4, the operations set
with p5 and p6 are performed.
When using the relative timer
XQ p1,p2,p3,p4,p5<terminator>
Syntax
p1 Timer number (1 or 2)
p2 Timer type (RELATIVE)
p3 Interval (fixed to HH:MM format)
HH
MM
Set the interval in the range 00:01 to 24:00
p4 Reset/not reset the data when the timer
expires (ON/OFF)
p5 Printout ON/OFF (ON, OFF)
Query
XQ[ p1]?
Example
Set a relative timer to timer number 1. Set the
interval to 1 hour 15 minutes, reset the data
when the timer expires, and disable printout.
XQ 1,RELATIVE,01:15,ON,OFF
4-22
Hour (00 to 23)
Hour (00 to 24)
Minute (00 to 59)
Description Each time the interval specified by p3 elapses
from the time the computation is started, the
operations set with p4 and p5 are performed.
UN
Changes the assignment of
channels to the recording pen
(pen model, /M1 option).
Syntax
UN p1,p2<terminator>
p1 Pen number (1 to 4)
p2 Channel number
UN[ p1]?
Query
Example
Assign computation channel 0A to pen number 4.
UN 4,0A
US
Sets the computation error
procedure (/M1 option).
US p1,p2<terminator>
Syntax
p1 Procedure taken when an error occurs.
+OVER
−OVER
p2 Procedure taken when the "input over" is
detected (procedure taken when an "input
over" value is applied to TLOG.SUM or
TLOG.AVE computation)
SKIP
LIMIT
US?
Query
Example
When the computed result is in error, handle the
error data as +OVER. Use the limit value given
by the recorder for computation instead of the
"input over" value.
US +OVER,LIMIT
YB
Sets the host name and domain
name (/C7 option).
Syntax
YB p1,p2<terminator>
p1 Host name (up to 64 characters)
p2 Domain name (up to 64 characters)
YB?
Query
Example
Set the host name to "ABC" and the domain
name to "recorder.co.jp."
YB ABC,recorder.co.jp
Description The settings specified by this command and
saved using the XE command take effect after
the recorder is power cycled.
YA
Sets the IP address (/C7 option).
Syntax
YA p1,p2,p3<terminator>
p1 IP address (0.0.0.0 to 255.255.255.255)
p2 Subnet mask
(0.0.0.0 to 255.255.255.255)
p3 Default gateway
(0.0.0.0 to 255.255.255.255)
Query
YA?
Handle error data as +OVER
Handle error data as –OVER
Do not use the data for
computation.
Use the limit value given by
the recorder for computation.