Omega RD100B User Manual page 57

Programmable recorder communication interface
Hide thumbs Also See for RD100B:
Table of Contents

Advertisement

4.4 Setting Commands
When the integration time is 100 ms;
6 channels: 2.5 s
12 channels: 5 s
18 and 24 channels: 10 s
VD
Sets the data display screen.
On screens without detailed parameters
Syntax
VD p1,p2<terminator>
p1 Screen number (01 to 15)
p2 Display type
4CH bargraph
4-channel bar graph display (pen
model)
6CH bargraph
6-channel bar graph display (RD100B
dot model)
Channel alarm status
Channel alarm status display
Time/Chart speed
Date/Time/Chart speed display
DI/DO
DI/DO status display
STATUS
Status display
System
System display
Light out
Screen OFF
SKIP
Skip
VD[ p1]?
Query
Example
Assign the status display to screen 02.
VD 02,STATUS
On screens with the displayed channel switching
interval
Syntax
VD p1,p2,p3<terminator>
p1 Screen number (01 to 15)
p2 Display type
1CH digital
1-channel digital display
2CH digital
2-channel digital display
4CH digital
4-channel digital display
6CH digital
6-channel digital display (dot model)
12CH digital
12-channel digital display (RD1800B
12, 18 and 24 dot model)
1CH digital+1CH bargraph
1-channel digital display + 1 channel
bar graph display
1CH digital+4CH bargraph
1-channel digital display + 4 channel
bar graph display (pen model)
4-16
2CH digital+2CH bargraph
2-channel digital display + 2 channel
bar graph display
Tag_1CH digital
1-channel digital display (tag)
Tag_2CH digital
2-channel digital display (tag)
Tag_1CH digital+1CH bargraph
1-channel digital display + 1 channel
bar graph display (tag)
Tag_1CH digital+4CH bargraph
1-channel digital display + 4 channel
bar graph display (tag, pen model)
p3 Displayed channel switching interval
MANUAL
AUTO1S
AUTO2S
AUTO3S
AUTO4S
AUTO5S
VD[ p1]?
Query
Example
Assign the 2-channel digital display to screen 04
and automatically switch the displayed channels
every 5 seconds.
VD 04,2CH digital,AUTO5S
For flag display
Syntax
VD p1,p2,p3<terminator>
p1 Screen number (01 to 15)
p2 Display type
FLAG
p3 Display ON/OFF for each channel
Specify the ON/OFF state of each channel
with 1 or 0 (see the explanation).
VD[ p1]?
Query
Example 1 On the 6-dot model, assign the flag display to
screen 03 and display the flags of channel 01
and 02.
VD 03,FLAG,110000
Example 2 On the 2-pen model with the computation
function (/M1 option), assign the flag display to
screen 03 and display the flags of measurement
channel 02 and computation channels 0A, 0B,
0E, and 0F.
VD 03,FLAG,01-11001100
Fixed display channels, data
update rate (pen model): 2 s,
data update rate (dot model):
scan interval
Switch the displayed
channels and data every
second.
Switch the displayed
channels and data every 2
seconds.
Switch the displayed
channels and data every 3
seconds.
Switch the displayed
channels and data every 4
seconds.
Switch the displayed
channels and data every 5
seconds.
Flag display (fixed)