Examples of LCD
Chip Error E17
RTC Failure
Chip Error E18
SATA1 Failure
Chip Error E19
SATA2 Failure
Chip Error E20
USB Failure
Chip Error E21
Ethernet Failure
HDx Error E22
HDx Can't Mount
HDx Error E23
HDx Is Faulty
SATAx Error
E24
COMM. Failure
These examples show the two-line display of a TS-IXL TeraStation. Rack-mount TS-RIXL TeraStations
have a slightly different LCD display, with the two lines of information displayed on a single line. Scroll
horizontally to view the rest of the information.
Firmware Updates
Visit Buffalo's web site (www.buffalotech.com) for the latest firmware updates for your TeraStation. Download the
update to your Windows desktop and run the update by double-clicking on it. It will detect TeraStations on your
network and give you the option of updating their firmware.
TeraStation IS Setup Guide
Meaning
The circuit board is damaged. Disconnect power for 10 seconds, then
reattach and boot the TeraStation. If the error persists, contact tech
support.
The circuit board is damaged. Disconnect power for 10 seconds, then
reattach and boot the TeraStation. If the error persists, contact tech
support.
The circuit board is damaged. Disconnect power for 10 seconds, then
reattach and boot the TeraStation. If the error persists, contact tech
support.
The circuit board is damaged. Disconnect power for 10 seconds, then
reattach and boot the TeraStation. If the error persists, contact tech
support.
The circuit board is damaged. Disconnect power for 10 seconds, then
reattach and boot the TeraStation. If the error persists, contact tech
support.
Failed to mount the hard drive. Format the hard disk. After formatting,
reboot the system. If the error is still displayed, replace the hard disk. If the
error persists, contact tech support.
An error occurred and the Xth hard disk was removed from the RAID array.
Replace the Xth hard drive.
Failed to communicate with the Xth hard drive. Reboot the TeraStation. If
the error persists, contact tech support.