Displayed Text
TEMP FLT:PSU
TEMP FLT:VC
TEMP WARN:CH
TEMP
WARN:MAG
TEMP WARN:VC
UNCERTAIN
LOAD
UNDER SPKR
CNT
VHF FAULT
VOLTAGE CLIP
WRONG LOAD
Table 9-1: Warning, Fault and Mute Indications (alphabetical by LCD Text / Event Log Text)
72
PLM Series Operation Manual rev 1.1.9
Event Log Text
Category
Temp Fault: Power
Fault
Supply Unit
Temp Fault: Speaker
Fault
Voice Coil
Temp.Warning;
Warning
Channel
Temp.Warning;
Warning
Speaker Magnet
Temp.Warning;
Warning
Speaker Voice-Coil
Uncertain About Load
Warning
Type
Under Speaker Count
Warning
Channel Fault: Very
Fault
High Frequency
n/a
Fault
Load Type / Routing
Fault
Mismatch
Type
Description
Power supply
The temperature of the PLM's PSU
temperature
has exceeded its safety limit.
Speaker Voice Coil
The temperature of the speaker
temperature fault
voice coil (estimated by Speaker-
Safe) has exceeded the manufac-
turers' recommended maximum.
Power output
High temperature in the power
temperature warning
output stage.
Speaker magnet
The temperature of the speaker
temperature
magnet is high (estimated by
SpeakerSafe).
Speaker voice coil
The temperature of the speaker
temperature
voice coil is high (estimated by
SpeakerSafe).
Load uncertainty
When speaker Fingerprints are
taken a tolerance band is also
defined to take into account
production variations. If LoadSmart
results lie in this band a Load
uncertainty warning results. The
user should re-check the load and
if all appears to be correct it is likely
that normal operation will result.
Fewer Speakers
A higher load impedance has been
measured than was predicted by
the Load Library for the assigned
speaker type.
VHF at output
An exceptionally high level of
continuous HF has been detected
at the PLM's power output stage.
Voltage limiter active
The peak voltage at the output
terminals has exceeded the
user-defined safe maximum.
Load type mismatch
LoadSmart is measuring load
characteristics which differ from
those of the assigned speaker type.