5.3.1.2 High SPL Profiles
High SPL profiles do not use the adaptive release time feature. High SPL profiles optimized for high frequen-
cies use less of the look-ahead delay peak-rounding feature; this feature is used most in the Sub profile and
least the HF profile.
Sub - The Sub profile is optimized for frequencies between 20 - 200 Hz
LF - The LF profile is optimized for frequencies between 20 - 1200 Hz
MF - The MF profile is optimized for frequencies between 300 - 6000 Hz
HF - The HF profile is optimized for frequencies above 1 kHz
Table 5-3 shows the theoretical maximum output power for a given load impedance and ISVPL setting.
An ISVPL-to-load calculator that will assist in generating the
appropriate ISVPL setting for a desired power load is available
at www.labgruppen.com/plm
Load Impedance (ohms)
ISVPL SETTING (V peak)
These ratings shown in Table 5-3 are limited by the
CPL (Current Peak Limiter) functions, not by ISVPL
settings, due to power output channel current
capacity.
MAX. SINEWAVE BURST POWER (Watts)
2
2.67
194
9409
7048
193
9312
6984
181
8190
6143
167
6972
5229
153
5852
4389
121
3660
2745
101
2550
1913
83
1722
1292
70
1225
919
56
784
588
47
552
414
38
361
271
17.8
79
59
Table 5-3: ISVPL-to-output examples
Operation and Performance
4
8
16
4705
2352
1176
4656
2328
1164
4095
2048
1024
3486
1743
872
2926
1463
732
1830
915
458
1275
638
319
861
431
215
613
306
153
392
196
98
276
138
69
181
90
45
40
20
10