Lab.gruppen PLM series Operation Manual page 62

Plm series powered loudspeaker management systems
Hide thumbs Also See for PLM series:
Table of Contents

Advertisement

Front Panel Interface
Soft Reset
A Soft Reset will reset all settings and parameters to the original factory-defined default values, but retains
Frame Preset information and IP / Network configuration. A power cycle is not required to complete this
type of reset.
7.11.5.3 Breaker Emulation Limiter (PLM 20000Q ONLY)
MENU > FRAME > BREAKEMULIM
The Breaker Emulation Limiter (BEL) provides ampere selection (5-32 A) and breaker type selection
(CONSERVATIVE, FAST and SLOW). Select by pressing the adjacent button then use the rotary encoder to
change the parameter.
This option is only available for the PLM 20000Q.
7.11.5.4 Network
MENU > FRAME > NETWORK
Pressing the NETWORK button displays a further screen containing network configuration information.
All parameters are view-only on the front panel and are either not editable, or can only be adjusted via the
Lake Controller.
A summary at the top right of the screen confirms whether a valid connection is present for both Ethernet
ports, and whether the Lake Controller is online.
IP Addr: Displays the Internet Protocol address for the selected unit and can only be changed via the
Lake Controller software. Please refer to the Lake Controller Operation Manual for further details.
IP Mask: Displays the IP address subnet mask for the selected unit and can only be changed via the
Lake Controller software. Please refer to the Lake Controller Operation Manual for further details.
MAC: Displays the unique Media Access Control Ethernet address for the processor. This value cannot
be changed.
F.ID: Displays the Frame ID, a unique Lake product identifier that cannot be changed.
7.11.5.5 Latency Match
To turn Latency Match on or off, select the parameter using the adjacent button then change the status
using the rotary encoder.
When Latency Match is ON the LM 26 adds delay to match the overall processing delay of legacy Lake
Contour Pro 26 and Mesa Quad EQ products. Please refer to the Lake Controller Operation Manual for
further information.
56
PLM Series Operation Manual rev 1.1.9

Hide quick links: