The DataPlus will alert you to the Conditional Violation by flashing the Total
Ascent Time display until you descend below the required decompression stop
ceiling. If you descend below the required decompression ceiling before 5
minutes have elapsed, the DataPlus will continue to function as if no violation
had occurred. In this case, no off-gassing credit will be given, and for each
minute above the ceiling, 1
stop time.
The added penalty decompression time will have to be 'worked off' first before
obtaining off-gassing credit. Once the penalty time is worked-off, and off-
gassing credit begins, required decompression stop depths and time will decrease
toward zero and the TLBG will recede into the caution (C.Z.) zone. Upon entry
into the caution (C.Z.) zone, the DataPlus will revert to the No Decompression
Dive Mode.
If you stay above the required ceiling stop depth for more than 5 minutes, the
TLBG segments will flash and the Delayed Violation Mode will be entered.

DELAYED VIOLATION MODE

Three conditions will cause the DataPlus to enter the Delayed Violation Mode:
1. You remain Above the Required Decompression Ceiling Stop
Depth for more than 5 minutes (Fig. 60). As previously described, you
1
/
minutes of penalty time is added to decompression
2
DataPlus
FT
FT
DATA
PLUS
GLO
Fig. 60 - Delayed Violation
(>5 min above stop ceiling)
51