Advertisement

INSTALLATION AND OPERATION INSTRUCTIONS
MODEL CFL-18NG-B, CFL-24NG-B,
CFL-30NG-B, ST-CFL-24NG:

NATURAL GAS

LEAVE IT WITH THE APPLIANCE FOR OPERATION AND MAINTENANCE.
WARNING: If the information in this
manual is not followed exactly, a fire or
explosion may result causing property
damage, personal injury or loss of life.
- Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas
supplier's instructions.
• If you cannot reach your gas supplier, call
the fire department.
- Installation and service must be performed
by a qualified installer, service agency or
the gas supplier.
Copyright 2005
Heat & Glo, a brand of Hearth & Home Technologies
20802 Kensington Blvd., Lakeville, Mn 55044
Printed in U.S.A.
This product may be covered by one or more of the following patents: (United States) 4593510, 4686807, 4766876, 4793322, 4811534, 5000162, 5016609, 5076254, 5113843, 5191877, 5218953, 5263471,
5328356, 5341794, 5347983, 5429495, 5452708, 5542407, 5601073, 5613487, 5647340, 5688568, 5762062, 5775408, 5890485, 5931661, 5941237, 5947112, 5996575, 6006743, 6019099, 6048195, 6053165,
6145502, 6170481, 6237588, 6296474, 6374822, 6413079, 6439226, 6484712, 6543698, 6550687, 6601579, 6672860, 6688302B2, 6715724B2, 6729551, 6736133, 6748940, 6748942, D320652, D445174,
D462436; (Canada) 1297749, 2195264, 2225408; or other U.S. and foreign patents pending.
READ THIS MANUAL BEFORE INSTALLATION AND
Heat & Glo • CFL-18/24/30-B, ST-CFL-24 • 526-900 Rev. F • 7/05
MODEL CFL-18LP-B, CFL-24LP-B,
CFL-30LP-B, ST-CFL-24LP:
LP GAS (PROPANE)
Underwriters Laboratories
WARNING:
Improper installation, adjustment, alter-
ation, service or maintenance can cause
injury or property damage. Refer to the
owner's information manual provided with
this appliance. For assistance or addi-
tional information consult a qualified in-
staller, service agency or the gas supplier.
Please contact your Heat & Glo dealer with
any questions or concerns. For the number
of your nearest Heat & Glo dealer, please call
888-427-3973
Listed
1

Advertisement

Table of Contents
loading

Summary of Contents for Heat & Glo CFL-18NG-B

  • Page 1: Natural Gas

    INSTALLATION AND OPERATION INSTRUCTIONS MODEL CFL-18NG-B, CFL-24NG-B, MODEL CFL-18LP-B, CFL-24LP-B, CFL-30NG-B, ST-CFL-24NG: CFL-30LP-B, ST-CFL-24LP: NATURAL GAS LP GAS (PROPANE) READ THIS MANUAL BEFORE INSTALLATION AND LEAVE IT WITH THE APPLIANCE FOR OPERATION AND MAINTENANCE. WARNING: If the information in this...
  • Page 2: Table Of Contents

    Table of Contents SERVICE PARTS LIST ......................3 INTRODUCTION ......................15 ASSEMBLY ......................... 15 GAS LINE CONNECTION .................... 16 OPERATING GUIDELINES AND MAINTENANCE INSTRUCTIONS ......17 LP (PROPANE) INFORMATION ................... 17 SAFETY INFORMATION ....................18 LIGHTING INSTRUCTIONS ..................19 HIGH ELEVATION INSTALLATION ................20 WARRANTY POLICY ......................
  • Page 3: Service Parts List

    CFL-18-B Service Parts (NG, LP) Exploded Parts Diagram Beginning Manufacturing Date: 7/98 (GN, PL) Vue éclatée des pièces Ending Manufacturing Date: ______ * Part number list on following page. * La liste des numéros de pièce se trouve à la page suivante. Heat &...
  • Page 4 Service Parts List / Liste des pièces de rechange CFL-18-B IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When ordering, supply serial and model numbers to ensure correct service parts. / IMPORTANT : L'information fournie dans cette brochure n'est valide que pendant une courte période.
  • Page 5 CFL-24-B Service Parts (NG, LP) Exploded Parts Diagram Beginning Manufacturing Date: 7/98 (GN, PL) Vue éclatée des pièces Ending Manufacturing Date: ______ * Part number list on following page. * La liste des numéros de pièce se trouve à la page suivante. Heat &...
  • Page 6 Service Parts List / Liste des pièces de rechange CFL-24-B IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When ordering, supply serial and model numbers to ensure correct service parts. / IMPORTANT : L'information fournie dans cette brochure n'est valide que pendant une courte période.
  • Page 7 CFL-30-B Service Parts (NG, LP) Exploded Parts Diagram Beginning Manufacturing Date: 7/98 (GN, PL) Vue éclatée des pièces Ending Manufacturing Date: ______ * Part number list on following page. * La liste des numéros de pièce se trouve à la page suivante. Heat &...
  • Page 8 Service Parts List / Liste des pièces de rechange CFL-30-B IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When ordering, supply serial and model numbers to ensure correct service parts. / IMPORTANT : L'information fournie dans cette brochure n'est valide que pendant une courte période.
  • Page 9 ST-CFL-24 Service Parts (NG, LP) Exploded Parts Diagram Beginning Manufacturing Date: 7-98 (GN, PL) Vue éclatée des pièces Ending Manufacturing Date: ______ * Part number list on following page. * La liste des numéros de pièce se trouve à la page suivante. Heat &...
  • Page 10 Service Parts List / Liste des pièces de rechange ST-CFL-24 IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When ordering, supply serial and model numbers to ensure correct service parts. / IMPORTANT : L'information fournie dans cette brochure n'est valide que pendant une courte période.
  • Page 11 Gas Log Positioning MINIMUM FIREPLACE SIZE FRONT WIDTH : 23 ” (750mm) REAR WIDTH : 19 ” (521mm) TOP VIEW DEPTH : 13 ” (331mm) HEIGHT : 22” (508mm) FIGURE 1. MODEL CFL-18-B Heat & Glo • CFL-18/24/30-B, ST-CFL-24 • 526-900 Rev. F • 7/05...
  • Page 12 Gas Log Positioning MINIMUM FIREPLACE SIZE FRONT WIDTH : 27 ” (750mm) REAR WIDTH : 22” (521mm) TOP VIEW DEPTH : 15 ” (331mm) HEIGHT : 22” (508mm) FIGURE 2. MODEL CFL-24-B Heat & Glo • CFL-18/24/30-B, ST-CFL-24 • 526-900 Rev. F • 7/05...
  • Page 13 Gas Log Positioning MINIMUM FIREPLACE SIZE FRONT WIDTH : 30” (750mm) REAR WIDTH : 24” (521mm) TOP VIEW DEPTH : 15 ” (331mm) HEIGHT : 22” (508mm) FIGURE 3. MODEL CFL-30-B Heat & Glo • CFL-18/24/30-B, ST-CFL-24 • 526-900 Rev. F • 7/05...
  • Page 14 Gas Log Positioning MINIMUM FIREPLACE SIZE FRONT WIDTH : 24” (521mm) REAR WIDTH : 24” (521mm) DEPTH : 17” (331mm) TOP VIEW HEIGHT : 20” (508mm) FIGURE 4. MODEL ST-CFL-24 Heat & Glo • CFL-18/24/30-B, ST-CFL-24 • 526-900 Rev. F • 7/05...
  • Page 15: Introduction

    1.0 INTRODUCTION CAUTION: CHECK THE CONSTRUCTION OF The information in this manual pertains to Models CFL- 18 NG/LP-B, CFL-24 NG/LP-B, CFL-30 NG/LP-B and THE FIREPLACE BEFORE INSTALLING THE GAS ST-CFL-24NG/LP. LOG SET. THE AREA OF THE FLUE SHOULD NOT BE LESS THAN 1/11 THE AREA OF THE FIREPLACE Gas Log Sets are Decorative Gas Appliances for Instal- OPENING NON-AIRTIGHT GLASS DOORS SHOULD lation in a Solid-fuel Burning Fireplace.
  • Page 16: Gas Line Connection

    B. Minimum inlet gas supply pressure for purposes of WARNING: OPEN THE CHIMNEY DAMPER TO ITS input adjustment, shall be 7.0 inches w.c. (1.75kPa) FULLY OPEN POSITION WHEN BURNING THIS GAS for natural gas and 11.0 inches w.c. (2.75kPa) for pro- LOG SET.
  • Page 17: Operating Guidelines And Maintenance Instructions

    3.0 OPERATING GUIDELINES AND MAINTENANCE INSTRUCTIONS Upon completing the gas line connection, a small amount CFL-18-B of air will be in the lines. When first lighting the pilot CFL-24-B light, it will take a few minutes for the lines to purge CFL-30-B themselves of this air.
  • Page 18: Safety Information

    SAFETY INFORMATION FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR DEATH. A. This appliance has a pilot which must be C. Use only your hand to push in or turn the gas lighted by hand.
  • Page 19: Lighting Instructions

    LIGHTING INSTRUCTIONS LIGHTING INSTRUCTIONS 1. "STOP!" Read the safety information on previous THERMOPILE PILOT BURNER page. 2. Open the control access cover (logs #3 and 4 in CFL models) or (logs #4 and 5 in ST-CFL model), refer to your Log Placement Instructions. 3.
  • Page 20: High Elevation Installation

    4.0 HIGH ELEVATION INSTALLATION for elevations between 2000 and 4500 feet in Canada. U.L. Listed gas appliances are tested and approved If the heating value of the gas has been reduced, these without requiring changes for elevations from 0 to 2,000 rules do not apply.
  • Page 21: Warranty Policy

    LIMITED LIFETIME WARRANTY HEAT & GLO GAS APPLIANCE PRODUCTS BASIC ONE-YEAR WARRANTY. HEAT & GLO, a brand of HEARTH & HOME TECHNOLOGIES INC., located at 20802 Kensington Boulevard, Lakeville, MN 55044, (“HEAT & GLO”) warrants to the original owner that your new HEAT & GLO Gas Appliance (the “Product”) will be free from defects in materials and workmanship for a period of one year from the date of installation.

Table of Contents