REMOVING THE POWER SUPPLY CORD
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Unplug cooktop or disconnect power.
2.
Remove the cooktop (see page 4-2 for the
procedure).
Power Supply Cord
3.
Remove the screw from the power supply
cord ground wire.
4.
Press the locking tab on the power supply
cord connector and disconnect it from the
main connector.
5.
Remove the strain relief from the power
supply cord and pull the cord out of the
burner box mounting hole.
Strain Relief
Power Supply Cord
4-13
Ground Wire Screw
Connector