5.
To remove the Crown burner gas valve:
a) Remove the spark switch from the Crown
burner gas valve (see step 3c).
b) Remove the six screws from the front
burner box access panel and remove
the panel.
Access Panel & 6 Screws
c) Disconnect the two wire connectors
from the from the switch terminals on
the Crown burner gas valve.
d) Push the locking tab and lift the switch
off the Crown burner gas valve holder
pins.
Crown Burner Gas Valve
e) Disconnect the two 1/2˝ gas line fittings
from the gas valve.
Gas Line Fittings
Switch
Pins
GY Wire
WH Wire
Locking Tab
f) Remove the screw from the gas manifold
clamp and remove the Crown burner
gas valve.
g) Check the rubber seal on the Crown
burner gas valve stem and make sure
that it is not cracked, or torn. If so, re-
place the seal.
4-6
Gas Manifold
Clamp Screw
Gas Valve
Seal