Removing The Spark Switches, And The Standard Or Crown Burner Gas Valves - KitchenAid KFGS306VSS Technical Education

Flush-mount gas cooktop
Hide thumbs Also See for KFGS306VSS:
Table of Contents

Advertisement

REMOVING THE SPARK SWITCHES, AND THE
STANDARD OR CROWN BURNER GAS VALVES
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Unplug cooktop or disconnect power.
2.
Remove the cooktop (see page 4-2 for the
procedure).
Gas Valves
NOTE: The spark switches are serviced as an
assembly and cannot be serviced separately.
3.
To remove the spark switches:
a) Remove the rubber covers from each
of the gas valves.
Gas Valve Covers
b) Pull the spark switches off each of the
standard gas valves. Pull the switches
straight out from the valves to unclip
and remove them.
Standard Burner
Spark Switch
c) To remove the spark switch on the (cen-
ter) Crown burner, use a small-blade
screwdriver, and pry the switch off the
valve. NOTE: When you reinstall the
spark switch on the Crown burner, press
down on the spark switch actuator so
that it fits under the valve actuator.
Spark Switch
Actuator
Continued on the next page.
4-4
Crown Burner
Valve
Actuator