Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
CROWN BURNER SWITCH
Refer to page 4-3 for the procedure for access-
ing the Crown burner switch.
1. Unplug cooktop or disconnect power.
2. Disconnect the wire connectors from the
switch terminals.
3. Set the Crown burner to the OFF position.
4. Set the ohmmeter to R x 1.
5. Touch the ohmmeter test leads to the switch
terminals. The meter should indicate an open
circuit (infinite).
6. Set the Crown burner to the LITE position.
The meter should indicate a closed circuit
0 Ω
R
E
I S
T S
A
N
E C
E T
T S
Primary Coil
Rp
Resistance
Secondary Coil
Rs 1-2
Resistance
Secondary Coil
Rs 2-3
Resistance
Secondary Coil
Rs 4-5
Resistance
Electrical Shock Hazard
Switch (N.O.)
TRANSFORMER TABLE
Y T
P
60 ± 6
4.7 ± 0.5
4.7 ± 0.5
306 ± 30
WARNING
POWER SUPPLY TRANSFORMER
Primary Connector
Refer to page 4-6 for the procedure for access-
ing the power supply transformer.
1.
Unplug cooktop or disconnect power.
2.
Disconnect the power supply transformer
primary (2-pin) connector.
3.
Set the ohmmeter to the R x 1 scale.
4.
Touch the ohmmeter test leads to the trans-
former connector pins. See transformer
table below.
U
I N
S T
Ω
Ω
Ω
Ω
5-2
C
O
N
D
T I
O I
N
S
22 °C
22 °C
22 °C
22 °C