Section 3: Installing The Fireplace; Step 1 Locating The Fireplace - Heat & Glo SL-350TRS-CE-D Installer's Manual

Hearth & home technologies gas fireplace installation manual
Hide thumbs Also See for SL-350TRS-CE-D:
Table of Contents

Advertisement

Step 1
Locating the
Fireplace
Clearance Requirements
The top and back of the
fireplace are defined by
stand-offs.
The heat shield must be
attached as shown if
combustible materials
are placed directly on
top standoffs (Figure 3).
The minimum clearance
to a perpendicular wall
extending past the face
of the fireplace is 7.62cm.
The back of the fireplac-
es may be recessed
into combustible con-
struction, as shown
below.
MODEL: SL-350TRS-CE-D
Minimum Clearances from the Fireplace to Combustible Materials
Glass
Floor
Front
91.4cm
0
10
The diagram below shows space and clearance
requirements for locating a fireplace within a room.
7.6 cm
A
NOTE:
*
Dimensions are
shown with the
sides, back
and/or corners
of the unit 1/2
inch from the
wall.
A
B
86.4cm
41.3cm
Figure 2. Fireplace Dimensions, Locations, and
Space Requirements
TOP STANDOFFS
Figure 3. Heat Shield
RECESSED DEPTH: 41.3cm
Back of
Sides of
Fireplace
Fireplace
1.3cm
1.3cm
Heat & Glo • SL-350TRS-CE-D • 2033-900 Rev. N • 10/07
B
E
C
1.3 cm
C
D
E
72.8cm
100.1cm 141.6cm
HEAT SHIELD
INSTALLED
HEAT SHIELD
Top of
Ceiling
Fireplace
3.8cm
79cm
3
Installing the
Fireplace
D