Step 10 Installing Trim, Logs & Ember Material; Installing The Trim - Heat & Glo SL-350TRS-CE-D Installer's Manual

Hearth & home technologies gas fireplace installation manual
Hide thumbs Also See for SL-350TRS-CE-D:
Table of Contents

Advertisement

CAUTION
1. Apply only non-
combustible
facing material
to the fireplace
surround.
Step 10
Installing Trim,
Logs, and
Ember Material
IF JOINTS BETWEEN THE FINISHED WALLS
AND THE FIREPLACE SURROUND (TOP AND
SIDES) ARE SEALED, A 150
SEALANT MATERIAL MUST BE USED. THESE
JOINTS ARE NOT REQUIRED TO BE SEALED.
ONLY NONCOMBUSTIBLE MATERIAL (USING
150
O
C. MINIMUM ADHESIVE, IF NEEDED) CAN
BE APPLIED AS FACING TO THE FIREPLACE
SURROUND. SEE THE DIAGRAM SHOWN
BELOW.
TOP SEAL
JOINT
SIDE
SEAL
JOINT
1,27 cm
Figure 43. Sealant Material

Installing the Trim

Combustible materials may be brought up to the
specified clearances on the side and top front
edges of the fireplace, but MUST NEVER overlap
onto the front face. The joints between the finished
wall and the fireplace top and sides can only be
°
sealed with a 150
C minimum sealant.
Install optional marble and brass trim surround kits
as desired. Marble, brass, brick, tile, or other
noncombustible materials can be used to cover up
the gap between the sheet rock and the fireplace.
Do not obstruct or modify the air inlet/outlet grilles.
When overlapping on both sides, leave enough
space so that the bottom grille can be opened and
the trim door removed.
WARNING: CHILDREN AND ADULTS
!
SHOULD BE ALERTED TO THE HAZ-
ARDS OF HIGH TEMPERATURES OF WORK-
ING SURFACES ON THESE HEATERS.
WORKING SURFACES INCLUDE ALL GLASS
PANELS AND DECORATIVE DOORS. YOUNG
CHILDREN SHOULD BE CAREFULLY SUPER-
VISED WHEN THEY ARE IN THE SAME ROOM
AS THE APPLIANCE.
Heat & Glo • SL-350TRS-CE-D • 2033-900 Rev. N • 10/07
O
C. MINIMUM
FINISH MATERIAL
MAY BE COMBUSTIBLE
-TOP AND SIDES OF UNIT-
1,27 cm
35

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents