Heat & Glo SL-350TRS-CE-D Installer's Manual
Heat & Glo SL-350TRS-CE-D Installer's Manual

Heat & Glo SL-350TRS-CE-D Installer's Manual

Hearth & home technologies gas fireplace installation manual
Hide thumbs Also See for SL-350TRS-CE-D:

Advertisement

Model:
SL-350TRS-CE-D
WARNING:
IF THE INFORMATION IN THESE
INSTRUCTIONS IS NOT
FOLLOWED EXACTLY, A FIRE OR
EXPLOSION MAY RESULT
CAUSING PROPERTY DAMAGE,
PERSONAL INJURY, OR DEATH.
-
Do not store or use petrol or other flam-
mable vapors and liquids in the vicinity of
this or any other appliance.
-
What to do if you smell gas
• Do not try to light any appliance.
• Do not touch any electrical switch.
• Do not use any phone in your building.
• Immediately call your gas supplier from
a neighbor's phone. Follow the gas
supplier's instructions
• If you cannot reach your gas supplier,
call the fire department.
-
Installation and service must be performed
by a qualified installer or competent
person.
Printed in U.S.A. Copyright 2007
Heat & Glo, a brand of Hearth & Home Technologies Inc.
20802 Kensington Blvd., Lakeville, MN 55044
This product is covered by one or more of the following patents: (United States) 4,112,913; 4,408,594; 4,422,426; 4,424,792; 4,520,791; 4,793,322;
4,852,548; 4,875,464; 5,000,162; 5,016,609; 5,076,254 5,191,877; 5,218,953; 5,328,356; 5,429,495; 5,452,708; 5,542,407; 5,613,487; (Australia)
543790; 586383; (Canada) 1,123,296; 1,297,746; 2,195,264; (Mexico) 97-0457; (New Zealand) 200265; or other U.S. and foreign patents pending.
Heat & Glo • SL-350TRS-CE-D • 2033-900 Rev. N • 10/07
READ THIS MANUAL BEFORE INSTALLING OR
OPERATING THIS APPLIANCE. THIS INSTALLERS
GUIDE MUST BE LEFT WITH APPLIANCE FOR
FUTURE REFERENCE.
WARNING: IMPROPER INSTALLATION,
ADJUSTMENT, ALTERATION, SERVICE
OR MAINTENANCE CAN CAUSE INJURY
OR PROPERTY DAMAGE. REFER TO
THIS MANUAL. FOR ASSISTANCE OR
ADDITIONAL INFORMATION CONSULT A
QUALIFIED INSTALLER OR
COMPETENT PERSON.
These instructions are only valid if the
following country symbol is on the appliance.
If this symbol is not present on the appliance,
it is necessary to refer to the technical
instructions which will provide the necessary
information concerning the modification of the
appliance to the conditions of use for the
country.
These instructions are valid for the following
countries: GB, IE
Please contact your Heat & Glo dealer with any
questions or concerns. For the number of your nearest
Heat & Glo dealer, please call 1-888-427-3973.
Installers Guide
0087
1

Advertisement

Table of Contents
loading

Summary of Contents for Heat & Glo SL-350TRS-CE-D

  • Page 1 4,852,548; 4,875,464; 5,000,162; 5,016,609; 5,076,254 5,191,877; 5,218,953; 5,328,356; 5,429,495; 5,452,708; 5,542,407; 5,613,487; (Australia) 543790; 586383; (Canada) 1,123,296; 1,297,746; 2,195,264; (Mexico) 97-0457; (New Zealand) 200265; or other U.S. and foreign patents pending. Heat & Glo • SL-350TRS-CE-D • 2033-900 Rev. N • 10/07 Installers Guide READ THIS MANUAL BEFORE INSTALLING OR OPERATING THIS APPLIANCE.
  • Page 2: Safety And Warning Information

    SAFETY AND WARNING INFORMATION Heat & Glo • SL-350TRS-CE-D • 2033-900 Rev. N • 10/07 READ and UNDERSTAND all instructions carefully before starting the installation. FAILURE TO FOLLOW these installation instructions may result in a possible fire hazard and will void the warranty.
  • Page 3: Table Of Contents

    Step 12 Lighting the Fireplace ... 39 After the Installation ... 39 Section 4: Maintaining and Servicing Your Fireplace ... 40 Section 5: Troubleshooting ... 42 = Contains updated information. Heat & Glo • SL-350TRS-CE-D • 2033-900 Rev. N • 10/07...
  • Page 4: Service Parts List

    SL-350TRS-CE-D Service Parts Service Parts Diagram Beginning Manufacturing Date: 9-03 Ending Manufacturing Date: _______ Log Set Assembly Part number list on following page. Heat & Glo • SL-350TRS-CE-D • 2033-900 Rev. N • 10/07...
  • Page 5 Conversion Kit B Pilot Orifice N Pilot Orifice P/ B Regulator N Regulator P/B Additional service part numbers may appear on following page. Heat & Glo • SL-350TRS-CE-D • 2033-900 Rev. N • 10/07 DESCRIPTION SL-350TRS-CE-D SERIAL # PART NUMBER LOGS-350CE-D...
  • Page 6 Flex Ball Valve Assembly Piezo Ignitor Wire Assembly On/Off Switch Assembly Valve N Valve P Valve Bracket Heat & Glo • SL-350TRS-CE-D • 2033-900 Rev. N • 10/07 Service Parts Valve assembly SL-350TRS-CE-D Beginning Manufacturing Date: 9-03 Ending Manufacturing Date: _______ SERIAL #...
  • Page 7: Section 1: Approvals And Regulations

    This appliance must be installed with the rules in force, and used only in a sufficiently ventilated space. Consult instructions before installation and use of this appliance. Heat & Glo • SL-350TRS-CE-D • 2033-900 Rev. N • 10/07 Appliance Certification The Heat & Glo fireplace models discussed in this Installers Guide have been tested to certification standards and listed by the applicable laboratories.
  • Page 8: Section 2: Getting Started

    Products, Inc., not withstanding any indepen- dent testing laboratory or other party approval of such component part or accessory. ANY SUCH ACTION MAY POSSIBLY CAUSE A FIRE HAZARD. Heat & Glo • SL-350TRS-CE-D • 2033-900 Rev. N • 10/07 Getting Started...
  • Page 9 153 mm TOP HEAT SHIELD (FLUE COLLAR COVER PLATE) ACCESS CONTROLS Figure 1. Diagram of the SL-350TRS-CE-D Heat & Glo • SL-350TRS-CE-D • 2033-900 Rev. N • 10/07 22-3/4 in. 577 mm 11-3/8 in. 289 mm 15-7/8 in. 402 mm 6-5/8 in.
  • Page 10: Section 3: Installing The Fireplace

    Minimum Clearances from the Fireplace to Combustible Materials Glass Back of Floor Front Fireplace 91.4cm 1.3cm Heat & Glo • SL-350TRS-CE-D • 2033-900 Rev. N • 10/07 7.6 cm 1.3 cm 86.4cm 41.3cm 72.8cm 100.1cm 141.6cm Space Requirements TOP STANDOFFS...
  • Page 11: Step 2 Framing The Fireplace

    Framing should be constructed of 2 X 4 lumber or heavier. 86,4 83,2 Figure 4. Framing Dimensions Heat & Glo • SL-350TRS-CE-D • 2033-900 Rev. N • 10/07 For Vertical Sections At Wall Firestops Bottom 2.54 cm 6.4 cm...
  • Page 12: Step 3 Installing The Flue System

    SL D-SERIES SLK-01DA SLK-991DA DVP-TVHW Figure 5. Flue Components and Terminations Heat & Glo • SL-350TRS-CE-D • 2033-900 Rev. N • 10/07 WARNING: YOU MUST NOT MIX DVP-SERIES AND SL D-SERIES COMPONENTS IN ANY FLUE SYSTEM CONFIGURATION. STORM COLLAR ROOF FLASHING...
  • Page 13 184mm 32mm TYP DVP48 13mm TYP 217mm 319mm NOTE: PIPES OVERLAP 32mm AT EACH JOINT. FIGURE 6. DVP-Series Balanced Flue Component Specifications (127mm inner pipe / 203mm outer pipe) Heat & Glo • SL-350TRS-CE-D • 2033-900 Rev. N • 10/07...
  • Page 14 NOTE: PIPES OVERLAP 34.93mm AT EACH JOINT. Figure 7. SL D-Series Flue Component Specifications (102mm inner pipe/168mm outer pipe) Heat & Glo • SL-350TRS-CE-D • 2033-900 Rev. N • 10/07...
  • Page 15 11.8m MAX. Use SL D-Series components only. Figure 8. Straight up Vertical Flue STRAIGHT OUT HORIZONTAL FLUE Max. Run 610mm Use DVP-Series components only. Figure 9. Straight Out Horizontal Flue Heat & Glo • SL-350TRS-CE-D • 2033-900 Rev. N • 10/07...
  • Page 16 NOTE: A 23 cm vertical section must be attached to the unit before the 90 elbow. Figure 11. Flue with One 90° Elbow Heat & Glo • SL-350TRS-CE-D • 2033-900 Rev. N • 10/07 Use DVP-Series components only. FLUE WITH ONE (1) 90 ELBOW MIN.
  • Page 17 H = MAX. 2.48 m H + H Use DVP-Series components only. Figure 12. Flue with Two 90° Elbows Heat & Glo • SL-350TRS-CE-D • 2033-900 Rev. N • 10/07 H + H MAX. 610 mm MAX. 1.22 m MAX. 1.22 m MAX.
  • Page 18 Use SL D-Series components only. Figure 13. Flue with Two 90° Elbows Heat & Glo • SL-350TRS-CE-D • 2033-900 Rev. N • 10/07 FLUE WITH TWO (2) 90° ELBOWS H + H MIN. 305mm MAX. 610mm MIN. 610mm MAX. 1.22m MIN.
  • Page 19 V + H + H USE DVP-SERIES COMPONENTS ONLY. Figure 14. Flue with three 90° elbows Heat & Glo • SL-350TRS-CE-D • 2033-900 Rev. N • 10/07 FLUE WITH THREE (3) 90° ELBOWS MAX. 610 mm MAX. 1.22 m MAX. 1.22 m MAX.
  • Page 20 H = MAX 2.48m H + H = MAX. 4.8m Figure 15. Flue with three 90° elbows Heat & Glo • SL-350TRS-CE-D • 2033-900 Rev. N • 10/07 H + H MAX. 1.22 m MAX. 2.48 m MAX. 3.7 m...
  • Page 21 DO NOT REMOVE HEAT SHIELD. ELEVATED HEADER TEMPERA- TURES MAY CAUSE A FIRE. Heat & Glo • SL-350TRS-CE-D • 2033-900 Rev. N • 10/07 Figure 17. Rotate the top heat shield to the vertical position as shown above. The heat shield must remain in the vertical position.
  • Page 22 Rear Flue Figure 23. Remove the insulation from the outer flue pipe. Heat & Glo • SL-350TRS-CE-D • 2033-900 Rev. N • 10/07 Figure 24. Cut the metal retaining band and fold the sides out. Figure 25. Fold the center parts of the retaining band out and us to remove the flue cap.
  • Page 23: Installing Flue Components

    To install support brackets for horizontal runs: • Place the pipe supports around the flue pipe. • Nail the pipe supports to the framing members. Heat & Glo • SL-350TRS-CE-D • 2033-900 Rev. N • 10/07...
  • Page 24 Heat & Glo • SL-350TRS-CE-D • 2033-900 Rev. N • 10/07 For Vertical Runs - The flue system must be supported every 2.4 m above the heater flue outlet by wall brackets. To install support brackets for vertical runs: • Attach wall brackets to the flue pipe and secure the wall bracket to the framing members with nails or screws.
  • Page 25 • Frame the hole with framing lumber the same size as the ceiling joists. 10" (254mm) FRAMING MEMBERS CEILING FIGURE 31. Hole and New Framing Members Heat & Glo • SL-350TRS-CE-D • 2033-900 Rev. N • 10/07 10" (254mm) 12" (305mm) 10” (254mm) CHIMNEY HOLE EXISTING CEILING...
  • Page 26: Flue Termination

    CAUTION: Heat & Glo • SL-350TRS-CE-D • 2033-900 Rev. N • 10/07 If the area above the ceiling is NOT an attic, position and secure the ceiling firestop on the ceiling side of the previously cut and framed hole. CEILING NAILS (4 REQUIRED) FIGURE 32.
  • Page 27 • Use a high-temperature sealant or fiberglass rope gas- ket to seal between the pipe and exterior firestop. • See Figure 37 for flue termination clearances. Heat & Glo • SL-350TRS-CE-D • 2033-900 Rev. N • 10/07 Rear Vent Heat Shield 38mm min.
  • Page 28 Heat & Glo • SL-350TRS-CE-D • 2033-900 Rev. N • 10/07 Figure 35. Termination cap For Vertical Terminations - To locate the flue and install the flue sections: • Locate and mark the flue centerpoint on the underside of the roof, and drive a nail through the centerpoint.
  • Page 29 16/12 to 18/12 over 18/12 to 20/12 over 20/12 to 21/12 Figure 36. Minimum Height from Roof to Lowest Heat & Glo • SL-350TRS-CE-D • 2033-900 Rev. N • 10/07 WARNING: FOLLOW NATIONAL REGULATIONS AND CODES OF PRACTICE FOR...
  • Page 30 Heat & Glo assumes no responsibility for the improper perfor- mance of the appliance when the venting system does not meet these requirements. Heat & Glo • SL-350TRS-CE-D • 2033-900 Rev. N • 10/07 (See Note 2) .91M Electrical...
  • Page 31: Securing The Fireplace

    Securing of a Fireplace WARNING: THIS UNIT IS NOT FOR USE WITH SOLID FUEL. WARNING: 230 VAC MUST NEVER BE CONNECTED TO A CONTROL VALVE IN A MILLIVOLT SYSTEM. STANDING PILOT Heat & Glo • SL-350TRS-CE-D • 2033-900 Rev. N • 10/07...
  • Page 32: Step 6 The Gas Supply Line

    The gas line should be installed by a qualified service technician. Heat & Glo • SL-350TRS-CE-D • 2033-900 Rev. N • 10/07 NOTE: Have the gas supply line installed by a qualified service technician in accordance with all building regulations.
  • Page 33: Step 7 Gas Pressure Requirements

    WARNING: DO NOT CONNECT 230 VAC TO THE GAS CONTROL VALVE OR THE APPLIANCE WILL MALFUNCTION AND THE VALVE WILL BE DESTROYED. Heat & Glo • SL-350TRS-CE-D • 2033-900 Rev. N • 10/07 Natural Gas (G25) 5.0 kW DMS 42...
  • Page 34: Step 9 Finishing

    Only non-combustible materials may be used to cover the black fireplace front. Heat & Glo • SL-350TRS-CE-D • 2033-900 Rev. N • 10/07 WARNING: DO NOT CONNECT 230 VAC TO THE WALL SWITCH OR THE CONTROL VALVE WILL BE DESTROYED.
  • Page 35: Step 10 Installing Trim, Logs & Ember Material

    -TOP AND SIDES OF UNIT- TOP SEAL JOINT SIDE SEAL JOINT 1,27 cm ° C minimum sealant. WARNING: CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZ- Heat & Glo • SL-350TRS-CE-D • 2033-900 Rev. N • 10/07 1,27 cm...
  • Page 36: Positioning The Logs

    BRACKET TAB Locate the bottom groove of log #2 over the left most grate bar and align over Heat & Glo • SL-350TRS-CE-D • 2033-900 Rev. N • 10/07 LOG PLACEMENT INSTRUCTIONS...
  • Page 37 Place the left end of log #4 in the groove on log #2 and the right end on log #1 as shown. LOG #5 (SRV438-724): Locate the top of log #5 onto log #1 and place the bottom on the right side of the fourth log grate. Heat & Glo • SL-350TRS-CE-D • 2033-900 Rev. N • 10/07...
  • Page 38: Placing The Ember Material

    (see Replacement Parts Section of the manual.) • Replace the latches and tension springs. DO NOT PLACE EMBERS BEHIND THE REAR BURNER PORTS. Figure 45. Placement of the Ember Material Heat & Glo • SL-350TRS-CE-D • 2033-900 Rev. N • 10/07 LATCHES (BOTH TOP AND BOTTOM)
  • Page 39: Step 11 Before Lighting The Fireplace

    ATION OF THE FIREPLACE. After the Installation WARNING: PLEASE REFER TO THE USER’S MANUAL FOR ALL CAUTIONS, SAFETY, AND WARNING INFORMATION LEAVE THIS INSTALLATION MANUAL WITH THE APPLIANCE FOR FUTURE REFERENCE. Heat & Glo • SL-350TRS-CE-D • 2033-900 Rev. N • 10/07...
  • Page 40: Your Fireplace

    As Service Technician necessary after initial cleaning. Heat & Glo • SL-350TRS-CE-D • 2033-900 Rev. N • 10/07 Stove Maintenance Task To Be Completed Brush away loose ember material near the burner. Replace old ember material with new 10mm thin pieces Glowing Ember (050-721).
  • Page 41 MAKE SURE THE FLAMES ARE STEADY—NOT LIFTING OR FLOATING. Figure 46. Burner Flame Patterns STANDING PILOT Figure 47. Pilot Flame Patterns Heat & Glo • SL-350TRS-CE-D • 2033-900 Rev. N • 10/07...
  • Page 42: Section 5: Troubleshooting

    Thermopile may not be generating sufficient millivoltage Heat & Glo • SL-350TRS-CE-D • 2033-900 Rev. N • 10/07 Corrective Action Check the spark at the electrode and pilot. If no spark and electrode wire is properly connected, replace the ignitor.
  • Page 43 Symptom and Possible Cause 1. a. above. Check the switch and wiring. Replace where defective. Clean and adjust the pilot flame for maximum flame impingement on thermocouple. Follow lighting instructions carefully. Heat & Glo • SL-350TRS-CE-D • 2033-900 Rev. N • 10/07...
  • Page 44 6. Glass soots. 7. Flame burns blue and lifts off burner. Heat & Glo • SL-350TRS-CE-D • 2033-900 Rev. N • 10/07 Symptom Possible Cause a. No LP in the tank b. Inner flue pipe...