• Important operating
a n d m a i n t e n a n c e
instructions included.
WARNING: If the information in these
instructions is not followed exactly, a fi re
or explosion may result causing property
damage, personal injury, or death.
• DO NOT store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of this
or any other appliance.
• DO NOT spray aerosols in the vicinity of this
appliance while it is in operation.
• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Immediately call your gas supplier from
a neighbor's phone. Follow the gas sup-
plier's instructions.
- If you cannot reach your gas supplier, call
the fi re department.
• Installation and service must be performed
by a qualifi ed installer, service agency, or the
gas supplier.
This is a room sealed appliance and no other ventilation is
required than what is provided.
NOTICE
DO NOT DISCARD THIS MANUAL
• Read, understand and follow
these instructions for safe
installation and operation.
Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14
Owner's Manual
Installation and Operation
• Leave this manual with
party responsible for use
and operation.
WARNING
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
Hot glass will cause burns.
• DO NOT touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as
fi replace.
• Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other fl ammable
materials.
• DO NOT place articles on or against this appliance.
• Keep clothing, furniture, draperies and other fl ammable
materials away.
This appliance has been supplied with an integral barrier
to prevent direct contact with the fi xed glass panel. DO
NOT operate the appliance with the barrier removed.
Contact your dealer or Hearth & Home Technologies if the
barrier is not present or help is needed to properly install one.
These instructions are only valid if the following country symbol is
on the appliance. If this symbol is not present on the appliance,
it is necessary to refer to the technical instructions which will
provide the necessary information concerning the modifi cation
of the appliance to the conditions of use for the country.
These instructions are valid for the following countries: GB
0086
1

Advertisement

Table of Contents
loading

Summary of Contents for Heat & Glo SL350TRSI-N-CE

  • Page 1 This is a room sealed appliance and no other ventilation is required than what is provided. These instructions are valid for the following countries: GB Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 2 Save this manual for future reference. Heat & Glo, a brand of Hearth & Home Technologies 7571 215 Street West, Lakeville, MN 55044 Copyright 2014 • Printed in U.S.A. Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 3: Congratulations

    Consult instructions before installa- tion and use of this appliance. XXXXXXXX Serial: DO NOT REMOVE OR COVER THIS LABEL. XXXX-XXX Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 4: Table Of Contents

    E. Control Module Operation ......55 Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 5 E. Contact Information ......80  = Contains updated information. Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 6: Limited Lifetime Warranty

    3 years Firebox and heat exchanger Lifetime All replacement parts 90 Days beyond warranty period See conditions, exclusions, and limitations on next page. 4021-645F 02-18-13 Page 1 of 2 Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 7 THE EXTENT PROVIDED BY LAW, HHT MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY SPECIFIED HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF THE EXPRESSED WARRANTY SPECIFIED ABOVE. 4021-645F 02-18-13 Page 2 of 2 Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 8: Listing And Code Approvals

    20/25 mbar 25 mbar Pmax 8.7 mbar 8.7 mbar 8.7 mbar 8.7 mbar Injector #44DMS #44DMS #44DMS #44DMS Effi ciency Class Electrical Requirements: 220/240V / 50 hz / 1A Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 9: High Altitude Installations

    fl ame proofed or not, or plastered or unplastered shall be considered combustible materials. G. Electrical Codes All electrical safety testing has been done following the EN 60335-2-102 standard. Local codes apply. Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 10: Operating Instructions

    DECORATIVE DOORS (NOT SHOWN) SECTION 2.E. FIXED GLASS ASSEMBLY (NOT SHOWN) SECTION 9.E. MANTEL SECTION 5.D HEARTH CLEAR SPACE SECTION 2.C. GRATE Figure 2.1 General Operating Parts Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 11: Clear Space

    Contact your dealer or Hearth & Home Technologies if the barrier is not present or help is needed to properly install one. For more information refer to the instructions supplied with your decorative door or front. Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 12: Control Module Operation

    fi replace after nine hours of continuous operation with receiving a command from the wall switch or optional remote. FLAME HI/LOW STATUS NG/LP GAS-TYPE SWITCH INDICATOR LED SELECTOR SWITCH  Figure 2.3 Control Module Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 13: Lighting Instructions (Ipi)

    For additional information on operating your Hearth & Home Technologies fi replace, please refer to www.fi replaces.com. Final inspection by Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 14: After Fireplace Is Lit

    Wall above appliance feels hot to No action necessary. This appliance ships with a non-combustible material attached. Specifi ca- the touch. tions of the attached non-combustible material are listed in Section 1.E. Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 15: Maintenance And Service

    • Carefully set fi xed glass assembly in place on fi replace. Hold glass in place with one hand and secure glass latches with the other hand. • Reinstall door or decorative front. Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 16 11.A for information related to the gas valve and gas sary. Refer to Section 14 for log placement instructions. pressure settings. • Verify correct log placement and no fl ame impingement causing sooting. Correct as necessary. Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 17 • Verify that there is not a short in fl ame sense circuit by checking continuity between pilot hood and fl ame sensing rod. Replace pilot as necessary. Figure 3.1 IPI Pilot Flame Patterns Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 18: Installer Guide

    FIREPLACE MUST BE INSTALLED MANTEL AND AND FLUE PENETRATION COMPLETE MANTEL LEG PRIOR TO FINISH SHEETING (SECTION 5.D) SURROUND HEARTH EXTENSION GAS LINE (SECTION 11) Figure 4.1 Typical System Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 19: Design And Installation Considerations

    High temperature caulking material (149 °C minimum continuous exposure rating) 1/2 - 3/4 in. length, #6 or #8 Self-drilling screws One 1/4 in. female connection (for optional fan). Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 20: Framing And Clearances

    16-1/2 13-1/2 7-1/2 34-3/4 27-3/4 5-7/8 68-3/4 SL350TRSI-N-CE See Section D, SL350TRSI-PB-CE Mantel Projections 102,3 86,4 142,3 123,2 41,9 34,3 19,1 88,3 70,5 91,4 119,4 14,9 1737 Figure 5.1 Appliance Locations Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 21: Constructing The Appliance Chase

    The framing headers may rest on the fi replace standoffs. Refer to Figure 5.1 and Figure 5.3 for fi replace and framing reference dimensions. Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 22 * Adjust framing dimensions for interior sheathing (such as sheetrock) C** Add 12 in. (30,5 cm) for rear venting with one 90º elbow. Figure 5.3 Clearances to Combustibles Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 23: Mantel And Wall Projections

    (Acceptable on both sides of opening.) HIGH TEMPERATURE (150 ºC MIN.) TOP AND SIDE SEAL JOINT Note: Zero clearance fi nishing allowed on sides of surround and top of non-combustible board. Figure 5.7 Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 24: Termination Locations

    53.1°-56.3° ............2 13 56.3°-59.0° ............2 29 59.0°-60.3° ............2 44 *.91 M minimum in snow regions Figure 6.1 Minimum Height From Roof To Lowest Discharge  Opening Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 25 All gravity air intakes within .91 m of a termination cap must be a minimum requirements. of .30 m below the termination cap. Figure 6.3 Minimum Clearances for Termination Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 26: Vent Information And Diagrams

    • When penetrating a combustible ceiling, a ceiling fi restop must be installed. • Horizontal runs of vent do not require vertical rise; Horizontal horizontal runs may be level. Figure 7.1 Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 27 SLP pipe 7 ft. (2,13 m) min. vertical = 11 ft. (3,35 m) max. horizontal Note: A 15,2 cm section of straight fl ue must be attached to the fi replace before a 90° elbow. USE SLP SERIES COMPONENTS ONLY Figure 7.4 Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 28 10 ft. 3,05 m 30 ft. 9,14 m 10 ft. 3,05 m = 30 ft. (9,14 m) Maximum = 10 ft. (3,05 m) Maximum INSTALLED HORIZONTALLY Figure 7.5 Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 29 3,66 m = 6 ft. (1,83 m) Maximum *H = 12 ft. (3,66 m) Maximum = 32 ft. (9,75 m) Maximum = 36 ft. (10,97 m) Maximum Figure 7.6 Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 30 Failure to keep insulation or other material away from vent pipe may cause over heating and fi re. For alternative installations, other than depicted, contact your dealer for further information. Figure 7.7 RESTRICTOR PLATE Figure 7.8 Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 31: Flue System Approvals And Installations

    PIPE LENGTH WALL FIRESTOP 90 DEGREE ELBOW CEILING WALL BRACKET FIRESTOP Flue system termination kits DVP-SERIES SLP SERIES DVP-TVHW DVP-TRAP2 DVP-FBHT SLP-TRAP2 SLP-TVHW Figure 7.9 Flue Components and Terminations Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 32 1,52 m 16 ft. 4,87 m = 36 ft. (10,97 m) Maximum *No specifi c restrictions on this value EXCEPT cannot exceed 32 ft. (9,75 m) Figure 7.10 Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 33 Note: A 15,2 cm section of straight fl ue must be attached to the fi replace before a 90° elbow. USE SLP SERIES COMPONENTS ONLY INSTALLED HORIZONTALLY Figure 7.11 Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 34 USE DVP SERIES COMPONENTS ONLY Figure 7.12 One 45º Elbow Do not use a 45º elbow in corner installations. Use two 90º elbows instead. USE DVP SERIES COMPONENTS ONLY Figure 7.13 Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 35 1,83 m 10 ft. 3,05 m INSTALLED HORIZONTALLY = 30 ft. (9,14 m) Maximum = 4 ft. (1,22 m) Maximum = 10 ft. (3,05 m) Maximum Figure 7.15 Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 36 4 ft. 1,22 m 10 ft. 3,05 m = 32 ft. (9,75 m) Maximum = 9 ft. (2,74 m) Maximum USE DVP SERIES COMPONENTS ONLY INSTALLED HORIZONTALLY Figure 7.17 Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 37 *No specifi c restrictions on this value EXCEPT cannot exceed 32 ft. (9,75 m) Maximum = 8 ft. (2,44 m) Maximum USE DVP SERIES COMPONENTS ONLY INSTALLED Figure 7.18 HORIZONTALLY Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 38: Vent Clearances And Framing

    * Shows center of vent framing hole for top or rear venting. The center of the hole is one 2,54 cm above the center of the horizontal vent pipe. Figure 8.2 Wall Penetration Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 39: Install The Ceiling Firestop

    INSTALL ATTIC INSULATION SHIELDS BEFORE OR AFTER INSTALLATION OF VENT SYSTEM 3 FASTENERS PER SIDE CEILING FIRESTOP CEILING FIRESTOP INSTALLED BELOW CEILING INSTALLED ABOVE CEILING Figure 8.4 Installing the Attic Shield Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 40: Install Attic Insulation Shield

    • Bend all tabs inward 90º around the top of the shield. These tabs must be used to prevent blown insulation from getting between the shield and vent pipe, and to maintain air space clearance. Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 41: Appliance Preparation

    The heat shield must remain in the vertical position. 2 SCREWS 2 SCREWS Figure 9.3 Replace the two screws as shown. Figure 9.6 Remove the insulation from the outer vent pipe. Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 42: Rear Vent

    Use two self- tapping screws to secure gasket to outer wrap. Figure 9.9 Cut the metal retaining band and fold the sides out. Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 43: Installing The Non-Combustible Board

    PILOT HOLES • Bend out nailing tabs on each side. • Place the appliance into position. Figure 9.16 Proper Positioning and Securing of an Appliance Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 44: Covers Removal For Servicing

    3/8 in. 7/16 in. the top two screws locating the pilot bracket (see Figure SL350TRSI-PB-CE (0,95 cm) (1,11 cm) 9.18). Slide the burner away from the burner orifi ce. Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 45: Installing Vent Pipe (Dvp And Slp Pipe)

    fl ue at the horizontal elbow joint to prevent the elbow from rotating. Use screws no longer than 1/2 in. (1,3 cm). If predrilling screw holes, DO NOT penetrate inner pipe. INCORRECT Figure 10.4 Seams Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 46: Assemble Vent Sections (Slp Pipe Only)

    • Only outer pipes are sealed, sealing the inner fl ue is not required. • All unit collar, pipe, slip section, elbow and cap outer fl ues shall be sealed. Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 47: Secure The Vent Sections

    Figure 10.10 Rotate Seams for Disassembly 120º Figure 10.11 Align and Disassemble Vent Sections Figure 10.8 Securing Vertical Pipe Sections 120º Figure 10.9 Securing Horizontal Pipe Sections Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 48: Install Support Brackets

    • The pipe opening of the fi restops MUST BE placed towards the bottom of the fi restop. Figure 10.14 Hole and New Framing Members • Continue the fl ue run through the fi restop. Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 49: Flue Termination

    • The small leg in the shield rests on top of the fl ue to properly space it from the pipe section (see Figure 10.17). Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 50: Heat Shield Requirements For Horizontal Termination

    • Caulk the perimeter of the fl ashing where it contacts the roof surface. See Figure 10.20. • Caulk the overlap seam of any exposed pipe sections that are located above the roof line. Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 51: Assemble And Install Storm Collar

    • Tighten nut and make sure the collar is tight against the pipe SCREWS section. CAULK • Caulk around the top of the storm collar. See Figure 10.21 Figure 10.22 Figure 10.22 Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 52: Gas Information

    20/25 mbar 25 mbar Pmax 8.7 mbar 8.7 mbar 8.7 mbar 8.7 mbar Injector #44DMS #44DMS #44DMS #44DMS Effi ciency Class Electrical Requirements: 220/240V / 50 hz / 1A Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 53: Gas Connection

    fl ame. Fittings and connections could have loos- ened during shipping and handling. WARNING! Risk of Fire! DO NOT change valve settings. This valve has been preset at the factory. Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 54: Electrical Information

    HARNESS TO OPTIONAL COMPONENTS OPTIONAL ON/OFF WALL SWITCH ORANGE GREEN (PILOT) (MAIN) BLACK BATTERY PACK 6V DC (C X 4) BROWN GROUND Figure 12.1 IPI Wiring Diagram /RC300CE Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 55: Blower

    See Figure 12.3 for wire connection de- tail. E. Control Module Operation See Section 2.I for control module operation instructions. Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 56 The RC300CE is approved for interior installation and should not be used in exterior applications. • Keep remote control out of reach of children. Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 57 Figure 12.7 Remote in Housing Figure 12.5 Temperature Scale 5. Close the housing door. See Figure 12.8. Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 58 3 min. ON, 12 min. OFF FAN CORD FAN CORD LEARN BUTTON Figure 12.11 Programming RC300CE AUX 300 AUX 300 MODULE MODULE Figure 12.10 Plug Fan into AUX300CE Module Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 59 Use the SELECT button to select the current Select feature. Use the UP and DOWN arrows to toggle through the menu functions and value selec- tions in the submenus. Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 60 fi replace is turned on. and AUX2 settings will be restored to the previous setting. NOTICE: The system will remember the previous FLAME HEIGHT setting and will automatically adjust after 10 seconds. Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 61 • Press and hold the MENU and UP arrow buttons simul- taneously for 4 seconds to enable or disable the child lock feature. NOTICE: No functions will be usable until child lock feature is disabled. Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 62 At control module, turn off fi replace by sliding the ON/OFF/ Remote control or control REMOTE switch to OFF. Warning! Risk of Burns! Fireplace is module failure hot. Use caution when accessing module. Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 63: Finishing

    SL350TRSI-N-CE Centimeters 74,1 83,7 MINIMUM SL350TRSI-PB-CE 91,44 cm MAXIMUM Figure 13.3 Noncombustible Facing Diagram Figure 13.2 Combustible Mantel Leg or Wall Projections (Acceptable on both sides of opening) Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 64: Appliance Setup

    Hearth & Home Technologies-approved optional acces- sories with this appliance. Using non-listed accessories could result in a safety hazard and will void the warranty. DO NOT MODIFY THIS APPLIANCE Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 65: Log Placement Instructions

    LOG #2 (SRV2033-701): Locate the bottom groove of log #2 over the left most grate tine and align over the burner by placing the log slot over the burner tab as shown. Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 66 LOG #5 (SRV438-724): Locate the top of log #5 onto log #1 and log #3, and place the bottom on the right side of the fourth grate tine. Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 67 LOG #6 (SRV540-704): Place log #6 against the second and third grate tines. If sooting occurs, the logs might need to be repositioned slightly to avoid excessive fl ame impingement. Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 68: Troubleshooting

    Verify module is securely grounded to metal chassis of appliance. d. Module voltage output / Valve/Pilot Verify battery voltage is at least 5.7 volts. Replace batteries if volt- solenoid ohms readings. age is below 5.7. Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 69 ON position. If there is no spark at “I” terminal module must be replaced. If there is a spark at “I” terminal, module is fi ne. Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 70: Reference Materials

    ELECTRICAL ACCESS Location Centimeters Location Centimeters 83,8 22,3 71,4 41,4 61,3 38,4 57,8 74,1 28,9 40,3 17,5 16,8 54,1 82,7 15,3 98,4 20,3 71,2 Figure 16.1 Appliance Dimensions Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 71: Maintenance Tasks

    4. Inspect for corrosion or separation. 5. Verify weather stripping, sealing and fl ashing remains intact. Remote controls 1. Verify operation of remote. 2. Replace batteries in remote transmitters and battery-powered receivers. Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 72: Vent Components Diagrams

    14 in. (35,6 cm) 12 in. (30,5 cm) 5 in. (12,7 cm) 6 in. (15,2 cm) DVP-HVS (Vent Support) DVP-WS (Wall Shield Firestop) Figure 16.2 DVP vent components Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 73 (35,6 cm) 3/8 in. (1,0 cm) 1 in. (2,5 cm) 7-3/4 in. to 10-3/8 in. (19,7 cm to 26,4 cm) DVP-FBHT FireBrickTermination Cap Figure 16.3 DVP vent components Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 74 13-1/4 in. (36,7 cm) 14 in. 27-1/2 in. (35,6 cm) 24-5/8 in. (12,7 cm) (62,5 cm) DRC-RADIUS RF6M Cap Shield Roof Flashing Multi-pak Figure 16.4 DVP vent components Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 75 51 - 15,2 SLP-WS SLP-PIPE Wall Shield Firestop SLP12A 2 - 12 51 - 30,5 SLP-HVS SLP-FS Horizontal Pipe Ceiling Firestop Support Figure 16.5 SLP Series Vent Components Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 76 Trap2 12 in. 13,3 cm 23,5 cm Length (30,5 cm) SLP-TRAP2 Horizontal Termination Cap SLP-TVHW Vertical Termination Cap DVP-FBHT DVP-FBHT SL-2DVP SLP90 Figure 16.6 SLP Series Vent Components Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 77: Service Parts

    2033-020 Lower Door Assembly 2033-042 Lower Door Stop 2033-125 Power Cord Assembly 2166-374 Blower 240 Volt Assembly , Optional GFK-240V Additional service parts appear on following page. 3/14 Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 78 17.16 Battery Pack** 4067-223 **Fuse for battery pack can be sourced locally, not a warranty item. Specs are 500mA~10A 3/4” long Additional service parts appear on following page. Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 79 Wire Assembly, Manual Reset 2201-030 Conversion Kits Natural to Propane/Butane N2PB-350I-CE Propane to Butane P2B-350I-CE Propane/Butane to Natural PB2N-350I-CE Pilot Orifi ce N .020 2098-520 Pilot Orifi ce B .0121 2098-512 Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...
  • Page 80: Contact Information

    5890485, 5941237, 6006743, 6019099, 6053165, 6145502, 6374822, 6484712, 6601579, 6769426, 6863064, 7077122, 7098269, 7258116, 7470729, 8147240 or other U.S. and foreign patents pending. 2000-945B Printed in U.S.A. - Copyright 2014 Heat & Glo • SL350TRSI-N-CE, SL350TRSI-PB-CE • 2033-980 Rev. L • 3/14...