Symptom
5. The pilot and main
a. No LP in the tank
burner extinguish
while in operation.
b. Inner flue pipe
c. Horizontal flue
d. Glass too loose and
e. Bad thermopile or
f. Improper flue cap
6. Glass soots.
a. Flame impingement
b. Improper venturi
c. Debris around
a. Insufficient oxygen
7. Flame burns blue
and lifts off burner.
Heat & Glo • SL-350TRS-CE-D • 2033-900 Rev. N • 10/07
Possible Cause
Check the LP (propane) tank. Refill the
fuel tank.
Check for gas leaks.
leaking exhaust
gases back into the
system
The horizontal flue cap should slope
down only enough to prevent any water
improperly pitched
from entering the unit. The maximum
downward slope is 6 mm.
Tighten the corner.
air tight packet leaks
in corners after
usage
Replace if necessary.
thermocouple
Check for proper installation and
freedom from debris or blockage.
installation
Adjust the log set so that the flame
does not excessively impinge on it.
Adjust the air shutter at the base of the
burner.
setting
Inspect the opening at the base of the
burner. NO MATERIAL SHOULD BE
venturi
PLACED IN THIS OPENING.
Ensure that the flue cap is installed
properly and free of debris. Ensure that
being supplied
the flue system joints are tight and
have no leaks.
Ensure that no debris has been placed
in the area at the base of, or in the area
of, the air holes in the center of the
base pan beneath the burner.
Ensure that the glass is tightened
properly on the unit, particularly on top
corners.