Heat & Glo SL-36-Ultimate Owner's Manual
Heat & Glo SL-36-Ultimate Owner's Manual

Heat & Glo SL-36-Ultimate Owner's Manual

Fireplaces gas appliances
Table of Contents

Advertisement

Quick Links

Model:
SL-36-Ultimate
• Important operating
a n d m a i n t e n a n c e
instructions included.
WARNING: If the information in these
instructions is not followed exactly, a fi re
or explosion may result causing property
damage, personal injury, or death.
• Do not store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of
this or any other appliance.
• What to do if you smell gas
- Do not try to light any appliance.
- Do not touch any electrical switch. Do not
use any phone in your building.
- Immediately call your gas supplier from a
neighbor's phone. Follow the gas suppli-
er's instructions.
- If you cannot reach your gas supplier, call
the fi re department.
• Installation and service must be performed
by a qualifi ed installer, service agency, or the
gas supplier.
This appliance may be installed as an OEM installation in
manufactured home (USA only) or mobile home and must be
installed in accordance with the manufacturer's instructions and
the manufactured home construction and safety standard, Title
24 CFR, Part 3280 or Standard for Installation in Mobile Homes,
CAN/CSA Z240MH.
This appliance is only for use with the type(s) of gas indicated
on the rating plate.
CAUTION
DO NOT DISCARD THIS MANUAL
• Read, understand and follow
these instructions for safe
installation and operation.
Heat & Glo • SL-36-Ultimate • 2141-900 Rev. i • 5/11
Owner's Manual
Installation and Operation
• Leave this manual with
party responsible for use
and operation.
WARNING
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
Hot glass will cause burns.
• DO NOT touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as
fi replace.
• Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other fl ammable
materials.
• Keep clothing, furniture, draperies and other fl ammable
materials away.
This appliance has been supplied with an integral barrier
to prevent direct contact with the fi xed glass panel. DO
NOT operate the appliance with the barrier removed.
Contact your dealer or Hearth & Home Technologies if the
barrier is not present or help is needed to properly install one.
In the Commonwealth of Massachusetts:
• installation must be performed by a licensed plumber
or gas fi tter;
See Table of Contents for location of additional
Commonwealth of Massachusetts requirements.
Installation and service of this appliance should be
performed by qualifi ed personnel. Hearth & Home
Technologies suggests NFI certifi ed or factory trained
professionals, or technicians supervised by an NFI
certifi ed professional.
1

Advertisement

Table of Contents
loading

Summary of Contents for Heat & Glo SL-36-Ultimate

  • Page 1 Technologies suggests NFI certifi ed or factory trained This appliance is only for use with the type(s) of gas indicated professionals, or technicians supervised by an NFI on the rating plate. certifi ed professional. Heat & Glo • SL-36-Ultimate • 2141-900 Rev. i • 5/11...
  • Page 2 BTUH: 00,000 00,000 00,000 00,000 MIN. MIN. INPUT INPUT BTUH: BTUH: 00,000 00,000 00,000 00,000 Serial Serial XXXXXXXX XXXXXXXX ORIFICE ORIFICE SIZE: SIZE: #XXXXX #XXXXX #XXXXX #XXXXX (Serie): (Serie): Heat & Glo • SL-36-Ultimate • 2141-900 Rev. i • 5/11...
  • Page 3: Table Of Contents

    E. Contact Information ......58 D. Installing Roof Flashing and Vertical Termination Cap . . . 26  = Contains updated information. Heat & Glo • SL-36-Ultimate • 2141-900 Rev. i • 5/11...
  • Page 4: Listing And Code Approvals

    • A 110-120 VAC circuit for this product must be protected with ground-fault circuit-interrupter protection, in compliance with the applicable electrical codes, when it is installed in locations such as in bathrooms or near sinks. Heat & Glo • SL-36-Ultimate • 2141-900 Rev. i • 5/11...
  • Page 5: Requirements For The Commonwealth Of Massachusetts

    VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OB- of the installation. STRUCTIONS”. See Gas Connection section for additional Common- wealth of Massachusetts requirements. Heat & Glo • SL-36-Ultimate • 2141-900 Rev. i • 5/11...
  • Page 6: Getting Started

    Electric drill and bits (1/4 in.) Plumb line Safety glasses Level Manometer Voltmeter Tape measure Caulking material (300ºF minimum continuous exposure rating) 1/2 - 3/4 inch length, #6 or #8 Self-drilling screws Heat & Glo • SL-36-Ultimate • 2141-900 Rev. i • 5/11...
  • Page 7: Inspect Firebox

    • Cracks that penetrate entirely through the firebrick material. Inspection for cracking should be run when the appliance is cool. Cracks tend to close as the appliance heats up. Heat & Glo • SL-36-Ultimate • 2141-900 Rev. i • 5/11...
  • Page 8: Framing And Clearances

    • Clearances and Mantel Projections (Sections 3.C and 3.D) • Vent Clearances and Framing (Section 6). 1/2 in. Model Inches 41-1/2 17-1/4 45-1/4 SL-36-Ultimate Millimeters 1054 1150 1626 Figure 3.1 Appliance Locations Heat & Glo • SL-36-Ultimate • 2141-900 Rev. i • 5/11...
  • Page 9: Constructing The Appliance Chase

    Front of Opening Opening Opening Opening to Ceiling Floor Flooring Appliance Appliance Appliance (Vent Pipe) (Height) (Depth) (Width) Inches 17-1/4 41-1/2 32-1/2 Millimeters 1321 1054 Figure 3.2 Clearances to Combustibles Heat & Glo • SL-36-Ultimate • 2141-900 Rev. i • 5/11...
  • Page 10: Mantel Projections

    Figure 3.4 Clearances to Mantel Legs or Wall Projections (Acceptable on both sides of opening.) NON-COMBUSTIBLE FACING AND FINISHING MATERIAL Figure 3.3 Clearances to mantels or other combustibles above appliance Heat & Glo • SL-36-Ultimate • 2141-900 Rev. i • 5/11...
  • Page 11: Termination Locations

    In a staggered installation with both gas and wood or fuel oil terminations, the wood or fuel oil termination cap must be higher than the gas termination cap. Figure 4.3 Staggered Termination Caps Heat & Glo • SL-36-Ultimate • 2141-900 Rev. i • 5/11...
  • Page 12 • Vinyl protection kits are suggested for use with vinyl siding. Figure 4.4 Minimum Clearances for Termination  Heat & Glo • SL-36-Ultimate • 2141-900 Rev. i • 5/11...
  • Page 13: Vent Information And Diagrams

    (see Figure 5.1). DVP12A 3 to 12 76 to 305 DVP12MI 3 to 12 76 to 305 DVP24MI 3 to 24 76 to 610 Figure 5.2 DVP Pipe Effective Length Heat & Glo • SL-36-Ultimate • 2141-900 Rev. i • 5/11...
  • Page 14: Vent Diagrams

    = 30 ft. (9.1 m) Maximum* * If the horizontal component is less than 5 feet then the total vent run can be extended to 40 feet. INSTALLED HORIZONTALLY Figure 5.4 Heat & Glo • SL-36-Ultimate • 2141-900 Rev. i • 5/11...
  • Page 15 5 ft. 6 in. 15 ft. 6 ft. 6 in. 18 ft. 7 ft. 6 in. 21 ft. = 21 ft. Max = 40 ft. Max = 30 ft. Max* Figure 5.5 Heat & Glo • SL-36-Ultimate • 2141-900 Rev. i • 5/11...
  • Page 16 = 40 ft. Max = 30 ft. Max* * If the horizontal component is less than 5 feet then the total vent run can be extended to 40 feet. Figure 5.7 Heat & Glo • SL-36-Ultimate • 2141-900 Rev. i • 5/11...
  • Page 17 = 30 ft. Max* * If the horizontal component is less than 5 feet then the total vent run can be extended to 40 feet. INSTALLED HORIZONTALLY Figure 5.8 Heat & Glo • SL-36-Ultimate • 2141-900 Rev. i • 5/11...
  • Page 18: Vent Clearances And Framing

    * Shows center of vent framing hole for top venting. The center of the hole is one (1) inch (25.4 mm) above the center of the horizontal vent pipe. Figure 6.2 Exterior Wall Hole Heat & Glo • SL-36-Ultimate • 2141-900 Rev. i • 5/11...
  • Page 19: Vertical Penetration Framing

    • Field construct additional shield height if insulation is deeper than height of attic ATTIC SHIELD INSTALLED ATTIC SHIELD INSTALLED shield. ABOVE CEILING BELOW CEILING Figure 6.4 Installing the Attic Shield Heat & Glo • SL-36-Ultimate • 2141-900 Rev. i • 5/11...
  • Page 20: Appliance Preparation

    Failure to keep insulation, framing or other material away from the appliance may cause fi re. STEEL BACK SUPPORT Figure 7.1 Proper positioning, leveling and securing of an appliance Heat & Glo • SL-36-Ultimate • 2141-900 Rev. i • 5/11...
  • Page 21: Installing Non-Combustible Facing Material

    • Apply a non-combustible adhesive to attach tile, stone or other non-combustible fi nishing materials per manufacturer’s instructions. Figure 7.3 Complete Installation of Non-combustible Facing Material Heat & Glo • SL-36-Ultimate • 2141-900 Rev. i • 5/11...
  • Page 22: Installing Vent Pipe

    If slip section seals are broken during the removal of the termination cap, gas will leak and a fi re or explosion may occur. Do not break silicone seals on slip sections. Figure 8.2 Lances Heat & Glo • SL-36-Ultimate • 2141-900 Rev. i • 5/11...
  • Page 23 The other end of the MI pipe section can then be attached by fi tting another pipe section to it and snapping it together, as normal. Figure 8.8 Screws into Slip Section Heat & Glo • SL-36-Ultimate • 2141-900 Rev. i • 5/11...
  • Page 24: Disassembly Of Vent Sections

    Improper support may allow vent to sag or separate. Figure 8.9 Securing Vertical Pipe Sections Figure 8.11 Rotate Seams for Disassembly Figure 8.10 Securing Horizontal Pipe Sections Figure 8.12 Align and Disassemble Vent Sections Heat & Glo • SL-36-Ultimate • 2141-900 Rev. i • 5/11...
  • Page 25: Installing Heat Shield And Horizontal Termination Cap

    The small leg on the extended heat shield should rest on the top of the vent (pipe section) to properly space it from the pipe section. Heat & Glo • SL-36-Ultimate • 2141-900 Rev. i • 5/11...
  • Page 26: Installing Roof Flashing And Vertical Termination Cap

    • Combustible materials blocking cap may ignite. • Restricted air fl ow affects burner operation. NOTICE: Failure to properly caulk the roof fl ashing and pipe seams may permit entry of water. Figure 8.16 Heat & Glo • SL-36-Ultimate • 2141-900 Rev. i • 5/11...
  • Page 27 Figure 8.18 Assembling the Storm Collar Around the Pipe until it rests on the roof fl ashing. Caulk around the top of the storm collar (see Figure 8.15). Figure 8.17 Assembling the Storm Collar Heat & Glo • SL-36-Ultimate • 2141-900 Rev. i • 5/11...
  • Page 28: Gas Information

    Natural Gas Propane 5.0 inches 11.0 inches Minimum inlet pressure w.c. w.c. 14.0 inches 14.0 inches Maximum inlet gas pressure w.c. w.c. 3.5 inches 10.0 inches Manifold pressure w.c. w.c. Heat & Glo • SL-36-Ultimate • 2141-900 Rev. i • 5/11...
  • Page 29 Fire hazard. Do NOT change the valve settings. • This valve has been preset at the factory. • Changing valve settings may result in fi re hazard or bodily injury. Heat & Glo • SL-36-Ultimate • 2141-900 Rev. i • 5/11...
  • Page 30: Electrical Information

    3 volts. GROUND Note 2: Plug WSK-MLT wall switch CONTINUOUS 110VAC kit into the REM/AUX outlet on the SUPPLY junction box. Figure 10.1 Intellifi re Pilot Ignition (IPI) Wiring Diagram Heat & Glo • SL-36-Ultimate • 2141-900 Rev. i • 5/11...
  • Page 31: Optional Accessories Requirements

    Fire Hazard Modification of any parts or installation of damaged components will void the warranty, Figure 10.2 Light enclosure and you may possibly cause a fi re hazard. Heat & Glo • SL-36-Ultimate • 2141-900 Rev. i • 5/11...
  • Page 32 For exterior wall installations, it is recommended that the junction box be sealed with caulking material. This will minimize heat loss through this location and improve the accuracy of the automatic (thermostat) operation. Figure 10.4 Heat & Glo • SL-36-Ultimate • 2141-900 Rev. i • 5/11...
  • Page 33 NOTE: The controller will turn off the fi replace at 2 F over after 120 VAC power is restored. set point and turn it back on at 2 F below set point. Heat & Glo • SL-36-Ultimate • 2141-900 Rev. i • 5/11...
  • Page 34: Junction Box Installation

    Cover Plate outside firebox Copper ground attached GRN wire to GRN screw with inside box GRN wire Note: Do NOT wire 110VAC to wall switch. Figure 10.6 Junction Box Detail Heat & Glo • SL-36-Ultimate • 2141-900 Rev. i • 5/11...
  • Page 35: Finishing

    • Seal joints between the fi nished wall and appliance top and • Operation of louvers or doors. sides using only a 300ºF minimum sealant. • Access for service. Heat & Glo • SL-36-Ultimate • 2141-900 Rev. i • 5/11...
  • Page 36: Appliance Setup

    • Save the remaining ember materials for use during appliance servicing. The embers provided should be enough for 3 to 5 applications. Heat & Glo • SL-36-Ultimate • 2141-900 Rev. i • 5/11...
  • Page 37: Positioning The Logs

    Place grate on the base of the fi rebox surround- ing the burner. The grate should be centered on the burner and pushed back until it contacts the burner. Figure 12.3 2141-930 Heat & Glo • SL-36-Ultimate • 2141-900 Rev. i • 5/11...
  • Page 38 Figure 12.5 LOG #3: (SRV2062-703) Place log #3 on the burner in the same way but on the left front of the burner. Figure 12.6 Heat & Glo • SL-36-Ultimate • 2141-900 Rev. i • 5/11...
  • Page 39 #1 and place the lower end on log #3. The notch on the bottom of log #6 should rest on the wedge shape on the end of log #3. Figure 12.9 Heat & Glo • SL-36-Ultimate • 2141-900 Rev. i • 5/11...
  • Page 40: Glass Assembly

    Remove the two screws holding Burner Neck the pilot and the one screw from the front of the burner Shutter Sleeve Orifi ce Holder (see Figure 12.11). Figure 12.13 Heat & Glo • SL-36-Ultimate • 2141-900 Rev. i • 5/11...
  • Page 41: Grilles And Trim

    fi rebox and replacing two screws (see Figure 12.11). Move the air shutter to the open position and tighten the wing nut to secure it (see Figure 12.10). Heat & Glo • SL-36-Ultimate • 2141-900 Rev. i • 5/11...
  • Page 42: Operating Instructions

    • Glass door MUST be in place and sealed before operating appliance. • Only use glass door certifi ed for use with appliance. • Glass replacement should be done by qualifi ed technician. Heat & Glo • SL-36-Ultimate • 2141-900 Rev. i • 5/11...
  • Page 43: Lighting Appliance

    See installation and operating instructions accompanying appliance. For additional information on operating your Hearth & Home Technologies fi replace, please refer to www.fi replaces.com. Final inspection by Heat & Glo • SL-36-Ultimate • 2141-900 Rev. i • 5/11...
  • Page 44: After Appliance Is Lit

    Is it normal to see the pilot fl ame burn In an Intellifi re ignition system it is normal to see the pilot fl ame, but it should turn off when continually? ON/OFF is turned off. Heat & Glo • SL-36-Ultimate • 2141-900 Rev. i • 5/11...
  • Page 45: Troubleshooting

    fl ame lifts from pilot hood, the circuit is broken. A wrong orifi ce or too high an inlet pressure can cause pilot fl ame to lift. The sensor rod may be contaminated. Clean sensor rod with emery cloth. Heat & Glo • SL-36-Ultimate • 2141-900 Rev. i • 5/11...
  • Page 46 Verify module is securely grounded to metal chassis of appliance. d. Module voltage output / Valve/Pilot Verify battery voltage is at least 2.7 volts. Replace batteries solenoid ohms readings. if voltage is below 2.7. Heat & Glo • SL-36-Ultimate • 2141-900 Rev. i • 5/11...
  • Page 47: Maintaining And Servicing Appliance

    Clean: • Glass • Air passageways, grilles, control compartment • Burner, burner ports Risk of: • Fire • Delayed ignition or explosion • Exposure to combustion fumes • Odors Heat & Glo • SL-36-Ultimate • 2141-900 Rev. i • 5/11...
  • Page 48: Maintenance Tasks

    3. Verify batteries have been removed from battery back-up IPI systems to prevent premature battery failure or leaking. Light Bulbs 1. Replace as needed. See section 10 for instructions. Heat & Glo • SL-36-Ultimate • 2141-900 Rev. i • 5/11...
  • Page 49: Reference Materials

    Location Inches Millimeters Location Inches Millimeters 37-1/4 17-1/4 8-3/8 30-1/2 31-3/8 36-1/8 16-1/4 9-3/8 1043 17-7/8 33-1/2 20-1/2 59-1/2 1511 1321 2-1/8 2-1/4 34-1/2 2-5/8 Figure 16.1 Appliance Dimensions Heat & Glo • SL-36-Ultimate • 2141-900 Rev. i • 5/11...
  • Page 50: Vent Components Diagrams

    (254 mm) 14 in. (356 mm) 5 in. 12 in. (127 mm) (305 mm) 6 in. (152 mm) DVP-HVS (Vent Support) DVP-WS (Wall Shield Firestop) Figure 16.2 DVP vent components Heat & Glo • SL-36-Ultimate • 2141-900 Rev. i • 5/11...
  • Page 51 5-5/8 in. DVP-TRAP Trap1 Horizontal Termination Cap 105 mm 143 mm 6-3/4 in. 10-5/8 in. Trap2 171 mm 270 mm DVP-TRAP2 DVP-TRAP1 DVP-TRAPK2 DVP-TRAPK1 Figure 16.3 DVP vent components Heat & Glo • SL-36-Ultimate • 2141-900 Rev. i • 5/11...
  • Page 52 Trap Cap Brick Extension 11-5/8 in. (295 mm) 12-1/8 in. 7-1/8 in. (308 mm) (181 mm) 5-3/4 in. (146 mm) DVP-TRAPFL COOL-ADD Cap Shield Figure 16.4 DVP vent components Heat & Glo • SL-36-Ultimate • 2141-900 Rev. i • 5/11...
  • Page 53: Limited Lifetime Warranty

    3 years Firebox and heat exchanger Lifetime All replacement parts 90 Days beyond warranty period See conditions, exclusions, and limitations on next page. 4021-645C 12-29-10 Page 1 of 2 Heat & Glo • SL-36-Ultimate • 2141-900 Rev. i • 5/11...
  • Page 54 D. Limited Lifetime Warranty (continued) WARRANTY CONDITIONS: WARRANTY EXCLUSIONS: This warranty is void if: LIMITATIONS OF LIABILITY: 4021-645C 12-29-10 Page 2 of 2 Heat & Glo • SL-36-Ultimate • 2141-900 Rev. i • 5/11...
  • Page 55: Service Parts List

    5647340, 5890485, 5941237, 5947112, 5996575, 6006743, 6019099, 6053165, 6145502, 6170481, 6374822, 6484712, 6601579, 6769426, 6863064, 7077122, 7098269, 7258116, 7470729 or other U.S. and foreign patents pending. 2000-945 Printed in U.S.A. - Copyright 2011 Heat & Glo • SL-36-Ultimate • 2141-900 Rev. i • 5/11...