Replacing Power Backplane - Fujitsu PRIMERGY TX150 S2 Manual

Hide thumbs Also See for PRIMERGY TX150 S2:
Table of Contents

Advertisement

Removal/installation routines

Replacing power backplane

Requirements
– server has been switched off
– power cords have been disconnected
– left side cover has been removed
– all power supply modules have been removed
The power backplane is mounted on the power supply cage. The power supply
cables are unremovable connected to the power backplane.
Ê Lay the floorstand model on a flat surface with the uncovered side facing
upwards.
This step has to be carried out by two people as the server may
!
weight up to 28 kg.
Ê Remove the air duct.
Ê Disconnect all power cables of the redundant power supply.
For the cabling see
Ê Remove the knurled screw (see circle) which fasten the power backplane to
the power supply cage.
Ê Push the power backplane somewhat downwards to release it from the three
guiding bolts (see arrows).
Ê Take the power backplane out of the server.
The installation of the new power backplane is done in reverse order.
U41057-J19-Z146-1-76
page
02-TX150S2-59.
July 2004
Power supply