Removal/installation routines
Ê Fix the locking rail with four screws (1) on the rear side of the server.
Ê Fix the power supply cage with three screws (2).
Ê Connect all boards and devices to the new power supply. For the cabling see
page
02-TX150S2-59.
Ê Reinstall the air duct.
Ê Insert the power supply module.
The redundant power supply module automatically adjusts to the
i
proper voltage range.
Ê Install the dummy module.
Ê Close the server.
Ê Mount the anti-tilt bracket (see
Ê Connect the power supply module to a grounded power outlet with the power
cable supplied.
You will find the description of the indicators of the power supply module on
page
02-TX150S2-36.
After installing the redundant power supply the SDR (sensor data record)
!
data base must be updated. For this sequence you need the BIOS flash
diskette prepared before. This diskette contains the newest BIOS
version, the BMC firmware and the SDR data.