Replacing the power backplane

4.6
Replacing the power backplane
The power backplane is integrated in the power supply cage. It is necessary to
replace the total power supply cage.
Ê Open the server as described in the
Ê Remove the air duct as described in the
Ê Remove the hot-plug power supply units as described in the Operating
Manual.
Figure 15: Loosening the screws
Ê Loosen the two screws (see the circles) at the rear side of the power supply
cage.
Ê Push the power supply cage in direction of the server's front side until the
bolts on the bottom side of the power supply cage disengage from the
housing.
28
section "Preparation" on page
section "Preparation" on page
Service Supplement
Replacement routines
17.
RX330 S1
17.