Fit assembly kit and rack-mount the server
Ê Secure the telescopic rail without bracket (HL) with two screws M5 each in
the rack at the right support uprights.
Please note that the guide nubs of the telescopic rail next to the spring nuts
must fit into the holes in the support uprights.
Ê Mount the DataCenter rack cable management (articulated cable guide) as
described in the service item of the DataCenter rack (see module „System
components", item „DataCenter rack", section „Cable management").
Ê Mount the server (see
Ê Route the cables with the inserted server as described in the service item of
the DataCenter rack (see module „System components", item „Data Center
rack", section „Routing cables").
Mounting in the Classic rack
For mounting the server in the Classic (19-inch) rack the following parts from the
rack mounting kit S26361-F1331-L7 are necessary:
– two telescopic rails (assembled)
– protective hose for fibre channel optical waveguide cable
Ê Refer to the assembly instructions in the technical manual for the Classic
(19-inch) rack.
Ê Using the mounting aid (stencil) mark the position of the attachment points
for the telescopic rails and for the server (front panel) on the support uprights
(five height units).
Refer to the information on the mounting aid.
Ê Place the spring nuts to fasten the telescopic rails in the groove of the
support uprights at the marked attachment points.
Ê If necessary, adjust the position of the nuts in the groove until they lock into
the correct position.
02
TX150S2
148
page
02-TX150S2-154).
July 2004
Removal/installation routines
U41057-J19-Z146-1-76