Fujitsu PRIMERGY TX150 S2 Manual page 72

Hide thumbs Also See for PRIMERGY TX150 S2:
Table of Contents

Advertisement

Troubleshooting
„Critical" status condition during boot
(only SATA version)
This error message is displayed from the SATA RAID controller:
ID
MODE
----------------------------------------------------------------
1
1x2 Mirror
Problem
is
detected
A SATA hard disk drive from a RAID 1 or RAID 10 array has failed or is not
responding.
You will find information for error cause and how to eliminate the error in the
„FastTrak S150 TX4 User Manual", chapter „Troubleshooting & Tips" .
Further information is provided also in the manual on the SATA RAID controller
„Promise Array Management (PAM) for FastTrak S150 TX2plus, S150 TX4 and
TX4000 User Manual".
System will not boot after installing a new hard disk drive
(only SCSI version)
SCSI configuration incorrect (ultra-wide SCSI controller)
Ê Check in the SCSI configuration menu the settings for the hard disk
drives (SCSI Device Configuration) and the additional settings (Advanced
Configuration Options).
Drives are reported as "dead" at system boot
(only SCSI version)
This error message can occur, when the server has a RAID controller.
Configuration of the RAID controller is wrong.
Ê Check and correct with the configuration program of the RAID controller
the settings for the drives.
Further information can be found in the operating manual concerning the RAID
controller.
02
TX150S2
72
SIZE
TRACK-MAPPING
81000M
9847/255/63
with
Array:
July 2004
1
U41057-J19-Z146-1-76
Diagnostics
STATUS
Critical

Advertisement

Table of Contents
loading

Table of Contents