Replacing The Power Backplane - Fujitsu PRIMERGY RX600 S3 SAS Service Supplement Manual

Hide thumbs Also See for PRIMERGY RX600 S3 SAS:
Table of Contents

Advertisement

Replacing the power backplane

Replacement routines
4.12
Replacing the power backplane
The power backplane is located underneath the system board close to the SAS
backplane.
Requirements
– The server has been switched off
– The power cables have been unplugged
– The server has been pulled out of the rack
– The housing cover has been removed (see
page
23)
– The system board has been removed (see
page
39)
– The power supply units have been pulled out (see Operating Manual)
Ê Unplug the cables of the power backplane (that are still plugged in)
from the SAS backplane (see pos. "2" in table on
page 46
).
B
A
Figure 22: Removing the power backplane
Ê Undo the seven screws (A) of the power backplane and remove it (B).
To install the power backplane follow the above steps in reverse order.
42
Service Supplement RX600 S3 SAS

Advertisement

Table of Contents
loading

Table of Contents