Multitech MultiModem DID MT5634ZBA-DID User Manual page 26

Data/fax/did modem
Hide thumbs Also See for MultiModem DID MT5634ZBA-DID:
Table of Contents

Advertisement

MultiModemDID User Guide
Command:
Values:
Defaults:
Description:
Chapter 4 - AT Commands, S-Registers, Result Codes
+MS= Modulation Selection
See description.
See description.
This extended-format command selects modulation, enables or
disables automode, and specifies the highest downstream and
upstream connection rates using one to four subparameters.
The command syntax is
+MS=[ mod ][,[ automode ][,[0][,[ max_rate ][,[0][,[ max_rx_rate ]]]]]]<CR>
Subparameters that are not entered retain their current value.
Commas separate optional subparameters and must be
inserted to skip a subparameter. Example: +MS=,0<CR>
disables automode and keeps other settings at current values.
+MS=? Reports supported options in the format (list of supported mod
values),(list of supported automode values),(0),(list of
supported max_rate values),(0),(list of supported max_rx_rate
values). Example: +MS: (BELL103, V21, BELL212A, V22,
V22B, V23C, V32, V32B, V34, V90, V92), (0, 1), (0), (0-33600),
(0), (0-56000)
+MS? Reports current options in the format mod, automode, 0,
max_rate, 0, max_rx_rate. Example: +MS: V92, 1, 0, 31200, 0,
56000.
Subparameters
mod Specifies the preferred modulation (automode enabled) or the
modulation to use in originating or answering a connection
(automode disabled). The default is V92.
26