Instructions for the installer
3
Additional requirements for Freestanding and Elevated Cooking
Appliaces – (Measurements D & E)
Where D, the distance from the periphery of the nearest burner to a horizontal combustible
surface is less than 200 mm, then E shall be 10 mm or more, or the horizontal surface shall be
above the trivet. See insets above.
NOTES
1
Requirement 3 does not apply to a freestanding or elevated cooking appliance which is
designed to prevent flames or the cooking vessels from extending beyond the periphery of the
appliance.
2
The 'cooking surface area' is defined as that part of the appliance
3
where cooking normally takes place and does not include those parts of the appliance
containing control knobs.
4
For definition of hob, see Clause 1.4.64.
5
For definition of trivet, see Clause 1.4.109.
6
Consideration is to be given to window treatments when located near cooking appliances. See
Clause 5.3.4.

11.3 Gas connection

This appliance is suitable for installation with Natural Gas or
ULPG (propane/butane). Refer to page 43 for the relevant
burner pressure and appropriate injector sizes. When the
appliance is to be connected to Natural Gas then the
pressure regulator supplied must be fitted to the gas inlet. A
test point (for checking the gas pressure) is supplied either
with the regulator or as a separate fitting in the case of
ULPG (propane) appliances.
Connection of the appliance to the gas supply must be in
accordance with the requirements of AS5601. A ½" BSP
connector at the inlet is recommended and the gas supply
line to the appliance must be of adequate length to allow
sufficient
withdrawal
disconnection and be:
1. annealed copper pipe or;
2. flexible hose according to AS/NZ1869 & be at least Class "B", 10 mm diameter.
The appliance must be installed with provision to allow the gas to be turned off and
disconnected for servicing and removal of the appliance as required from the gas supply.
Before the appliance is operated make certain all relevant parts are placed in the correct
position. On completion of the installation, the installer MUST check for gas leaks and
test each burner individually for the correct flame. Once all burners have been tested
individually, turn all burners on together. Warranty service calls do not cover these
adjustments! To check the operating pressure of the appliance it is recommended at least
2 large size burners are used. Ensure appliance is secured to wall when installation is
completed.
N.G. The regulator supplied must be fitted to the ½ BSP thread at the rear of the
appliance. An approved manual shut-off valve must be installed. The N.G. regulator must
be checked and adjusted to 1.0kPa after installation.
of
appliance
for
service