Troubleshooting - Strong DiSEqC Positioner v50 User Manaul

Diseqc positioner v50
Table of Contents

Advertisement

PART 1 • English
Repeat Step 1 to 3 to set up all the satellites you prefer. However, for DiSEqC 1.0
receivers, only P01 ~ P04 can be used.
East (West)
/ Down
Recall a Satellite Position:
Change the DiSEqC 1.0 setting of the channels. The positioner will drive the dish to the right Satellites
while you change the channel. The Display will show "P01" ~ "P04"
Restore Factory Default (Reset):
This function will clear all data in the Positioner, includes High/Low Limits, Satellite Positions, ..., etc.
Unplug from the AC outlet. Press the Power button on the top of the positioner and re-plug to the AC
outlet. Keep pressing the Power button for 3 seconds. The Display will show 10, 9 ... 1, then reset the
system. To stop the Reset process, unplug from the AC outlet before counting to 1.

8.0 TROUBLESHOOTING

Symptoms
Can't work with DiSEqC 1.0
Receiver
Can't move to count less than 0
or more than 999.
The Stored Positions are not
correct.
The LED shows |- or -|, and
can't move more.
West (East)
Power /
Store
/ UP
1. Make sure position no.1 to 4 are stored.
2. After receive DiSEqC 1.2 commands, the DiSEqC 1.0 commands
will be ignored. Please operate the positioner by DiSEqC 1.2 receiver,
which is much better for motorization system.
The total position index of this Positioner is 2000 (0~1999),
which is enough for most of the application.
Use "Goto Position 0" Function to solve
1. Try to use the "*Re-calculate(Adjust Shift) function" to
correct the position first.
2. If it happens again and again, please replace the Reed
Sensor to check if the Sensor is stable
The symbols mean Electrical Limits, which have been set. If
you want to cancel this setting, use the "Limit Off Function"
from the receiver. And set the software limit again.
Manual Buttons
Check points