DiSEqC Positioner v50 User Manual DiSEqC 1.0 / 1.2 Receivers Compatible Work with any Receiver via Optional Remote Control Compatible with any Actuator or H-H Mount 60 Programmable Memories Easy Operation and Quick Installation Fine-tune Function for Better Reception Anti-Noise Circuit to avoid miscounting...
PART 1 • English 1.0 SAFETY PRECAUTIONS 1. The ventilation should not be impeded by covering the ventilation openings with items, such as newspapers, table-cloths, curtains, etc. 2. No naked flame sources, such as lighted candles, should be placed on the apparatus. 3.
Page 4
PART 1 • English Power On/Off RESET Lock/unlock the positioner Sat. No. keys (0-9) Cancel the previous command Enter Key Browse stored Satellite positions Store a Satellite position Set software east / west limits Manually adjust direction to Shift: Adjust all the stored East / West satellite positions...
PART 1 • English 3.0 BASIC OPERATION Front View Manual Buttons 3 Digit LED Display 1K Indicator 5 V DC (Optional for Optical Sensor Connect to Receiver and LNB Connect to Motor (Via Coaxial Cable) Pulse Ground (36 V DC Output) (Connect to Reed Switch Sensor) Manual Buttons For South Hemisphere:...
PART 1 • English Index 888 Index 1.888 1K Indica for Lights on 5.0 CABLE CONNECTION 1. Connect the Motor to the terminals printed M1 & M2, and connect the Reed Switch Sensor to the terminals printed SENSOR via Motor Cable. p.s.: The wrong connection between Motor &...
PART 1 • English 6.0 FOR ANY RECEIVER Optional Remote Control is necessary Set the Software High / Low Limits: Setting the software High / Low Limits are recommended for better protection even if there are Hardware Limit Switches on the actuator or H-H mount. However, the Positioner can be operated without setting the software High/Low Limits.
Page 8
PART 1 • English Enter Recall a Satellite Position: 1. Simply press Sat _ or Sat V button to browse 2. Input specific position number 1 ~ 60 on the remote control and press Enter button within 3 seconds, the positioner will drive the actuator to the intended position. p.s.
PART 1 • English Lock Enter Restore Factory Default (Reset): This function will clear all data in the Positioner, includes High/Low Limits, Satellite Positions, …, etc. 1. Unplug from the AC outlet. Press the Power button on the top of the positioner and re-plug to the AC outlet.
Page 10
PART 1 • English Store the Satellite Positions: 1. Drive the Actuator East / West until the picture on the TV screen is clear. 2. Choose a sat. no. 1 ~60 and then send Store command from the receiver. 3. The Display will show “C01~C60” then show “P01~P60”. Repeat Step 1 to 3 to set up all the satellites you prefer.
Page 11
PART 1 • English the Display will show “Er2” first then “000” which indicates the mechanical 0 position of the Actuator. Restore Factory Default (Reset): This function will clear all data in the Positioner, includes High/Low Limits, Satellite Positions, …, etc. Unplug from the AC outlet.
PART 1 • English Repeat Step 1 to 3 to set up all the satellites you prefer. However, for DiSEqC 1.0 receivers, only P01 ~ P04 can be used. Manual Buttons East (West) West (East) Power / / Down Store / UP Recall a Satellite Position: Change the DiSEqC 1.0 setting of the channels.
Page 13
PART 1 • English Symptoms Check points Er1 Message Make sure there is no short-circuit of the wire connection. (Over Current) Check if the Antenna is blocked by anything. Make sure the Motor works well. Some times a malfunction Or System Shut-down Motor can cause higher current.
PART 1 • English 9.0 DISPLAY DESCRIPTION 10.0 SPECIFICACTION Input Voltage 220 - 240 V AC 50Hz (110 V A C 60Hz Available) 13 / 18 V DC (F Type via Coaxial Cable) Output Voltage 13 / 18 V DC (F Type / According to the Input) 36 V DC (via Motor Cable).