Service Port Setting; Alarm Notification Setting - Mitsubishi Electric DX-TL2500E Installation And Operation Manual

Digital recorder
Hide thumbs Also See for DX-TL2500E:
Table of Contents

Advertisement

<INITIAL SET UP/INFORMATION> (continued)

• SERVICE PORT SETTING

The port number can be set here to connect personal
computer.
Do not change the setting without sufficient knowl-
edge about the network setting.
When perform other setting except "WEB", the spe-
cific software is required. Please refer to the instruc-
tion manual of the software.
1. Press the SET UP button } <SETTINGS> } <INITIAL SET
UP/INFORMATION> } <COMMUNICATION PORT
SETTINGS> } select "SERVICE PORT SETTING" in the
<ETHERNET> screen.
• The <SERVICE PORT SETTING> screen appears.
<SERVICE PORT SETTING>
>>WEB
USER ACCESS
SUPER USER
LIVE USER1
LIVE USER2
LIVE USER3
LIVE USER4
2. Turn the JOG dial to select the desired setting and turn the
SHUTTLE ring clockwise.
• The first figure of the port number reverses in color.
3. Turn the JOG dial to display the desired figure reversed in
color, and turn the SHUTTLE ring.
• The background of the selected figure turns red and flashes.
4. Turn the JOG dial to display the desired port number and
turn the SHUTTLE ring clockwise.
• The setting is confirmed and stops flashing.
When change the "WEB" setting, the " • " situated
on the left of the port number turns its color from green
to red.
5. To change other settings repeat steps 2 to 4.
6. Return to the <ETHERNET> screen by turning the SHUTTLE
ring and press the SET UP button.
7. When the setting is altered, the unit turns off automatically
and the setting will renew.

• ALARM NOTIFICATION SETTING

The setting is for the transmission of warning signals and
other signals for status changes such as the short-circuit
of the rear terminal or when initiated the recording.
The specific software is required. Please refer to
the instruction manual of the software.
Issuing of reports to broadcast addresses is not
supported.
1. Press the SET UP button } <SETTINGS> } <INITIAL SET
UP/INFORMATION> } <COMMUNICATION PORT
SETTING> } select "ALARM NOTIFICATION SETTING" in
the <ETHERNET> screen.
• The <ALARM NOTIFICATION SETTING> screen appears.
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
56
2. (Cases of setting the IP ADDRESS number of connected
PC, the port setting number, etc. • • • )
Turn the JOG dial to select the desired setting number and
turn the SHUTTLE ring clockwise.
• The leftmost figure of the port number reverses in color.
3. Turn the JOG dial to display the desired figure of numbers
of IP ADDRESS, TARGET PORT and OWN PORT reversed
•00080
in color and turn the SHUTTLE ring.
53705
• The background of the desired figure turns red and flashes.
53706
53707
4. Turn the JOG dial to display the desired number and turn
53708
the SHUTTLE ring clockwise.
53709
53710
• The setting is confirmed and stops flashing.
01023, the " • " situated on the left of the value turns red
from green, and in case of 01024 - 49151 turns yellow.
5. To change other setting number repeat steps 2 to 4.
6. (Cases of the setting of the transmission contents to
connected PC • • • )
Turn the JOG dial to select the desired setting and turn the
SHUTTLE ring clockwise.
• The background of the setting turns red and flashes.
Setting of "WARNING" ( default : "OFF" )
"ON" : Transmits warning signals to connected PC. E-
mail is sended to address displayed on "USER AD-
DRESS" of the <E-MAIL ADDRESS> screen.
"OFF" : Does not transmit.
Setting of "ALARM SENS" ( default : "OFF" )
"ON" : Only for the short-circuit of rear terminal trans-
mits the status information to connected PC. E-mail is
sended to address displayed on "USER ADDRESS" of
the <E-MAIL ADDRESS> screen.
"OFF" : Does not transmit.
Setting of "REC MODE" ( default : "OFF" )
"ON" : Transmits the recording status such as normal
recording or alarm recording to connected PC. E-mail
is sended to address displayed on "USER ADDRESS"
of the <E-MAIL ADDRESS> screen.
OFF : Does not transmit.
Setting of "RETRY TIME" ( default : "10S" )
1S, 2S, • • • •, 10S, • • • • • • 59S, 60S
7. Turn the JOG dial to display the desired setting and turn the
SHUTTLE ring clockwise.
• The setting is confirmed and stops flashing.
8. Turn the SHUTTLE ring counterclockwise to return to the
<ETHERNET> screen, and press the SET UP button.
<ALARM NOTIFICATION SETTING>
NO
IP ADDRESS
>>1 000.000.000.000•55111 01111
2 000.000.000.000•55111 01112
3 000.000.000.000•55111 01113
4 000.000.000.000•55111 01114
5 000.000.000.000•55111 01115
WARNING
ALARM SENS
REC MODE
RETRY TIME
When TARGET PORT number is set to 00000 -
TARGET OWN
OFF
OFF
OFF
10S