Operation example 4

This example illustrates the procedure for when the unit is
set to record from Monday to Friday, and archive the data
once a week with a timer function. The media can be made
to automatically eject after archive for easy replacement.
The "ARCHIVE OVERWRITE" and "ARCHIVE
MEDIA AUTO EJECT" on the <RECORDING SET-
TINGS> screen cannot be selected while making
TIMER SETTING.
< Operation >
Setting example of the unit and peripheral devices
• 16 cameras connected to the unit
• Archive device set to ID4
• Monitor
MONITOR
~
AC IN
< Operation >
• Set Monday-Friday, 00:00-24:00 to RECORD SETTING
A (all cameras normal recording "
• Archive 5 days worth of data on Monday from 00:00-05:00
on a peripheral recording device while continuing record-
ing as usual. After archive, automatically eject the media.
00:00
From Monday
to Friday
00:00
Only Sunday
ARCHIVE
< Setting >
1) Set 1) ~ 3) of "Operation example " 1 ".
2) <TIMER PROGRAM SETTINGS> screen setting
(
see pages 46-48 ).
• SELECTED PATTERN : "P1".
<TIMER PROGRAM SETTINGS>
>>SELECTED PATTERN
HOLIDAY SETTING
REC MODE A
REC MODE B
REC MODE C
REC MODE D
ALARM REC DURATION
3) <REAR TERMINAL SETTINGS> screen setting (
see page 54 ).
• EMERGENCY REC DURATION : "20M".
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• Operations
···
ID4 : ARCHIVE DEVICE
CAMERA
ON
MAIN
OFF
IN
1
2
3
4
5
6
7
8
9
10
11
12
13
14
OUT
MAIN OUT
SPOT OUT
AUDIO
GND
ALARM IN
OUT
IN
VIDEO
Y/C
RS-232C
REMOTE
ETHERNET
RESET
RS-485/
RECEIVE
SEND
RS-422
" ~ "
1
16
RECORD FOR 24HOURS
05:00
ARCHIVE MEDIA AUTO EJECT
P1-SET
4) <RECORD SETTING A> screen setting (
• All cameras ( "
• PPS, GRADE : Set desired interval and picture quality
for each camera.
• A-PPS : "- - - - - -".
<RECORD SETTING A> 1/2
<RECORD SETTING A> 2/2
IN
15
16
OUT
MIC
SCSI
").
5) <TIMER PROGRAM> screen setting (
46, 47 ).
• SPL : "MON - FRI".
• PROGRAM NO.1 : "SPL", "00:00", "00:00", "A", "OFF".
• PROGRAM NO.2 : "MON", "00:00", "05:00", "OVER-E",
"OFF".
24:00
When completed with all settings above and after clear-
ing the menu screen, press the TIMER button. The unit
will switch to the timer mode.
5M
" ~ "
" ).
1
16
<RECORD SETTING A> ALARM CH
NO
PPS
GRADE A-PPS
>>
1
1.563P STD
------ STD
2
1.563P STD
------ STD
3
1.563P STD
------ STD
4
1.563P STD
------ STD
5
1.563P STD
------ STD
6
1.563P STD
------ STD
7
1.563P STD
------ STD
8
1.563P STD
------ STD
9
1.563P STD
------ STD
NEXT PAGE
SHUTTLE<<:BACK
<RECORD SETTING A> ALARM CH
NO
PPS
GRADE A-PPS
>>
10
1.563P STD
------ STD
11
1.563P STD
------ STD
10
12
11
1.563P STD
------ STD
13
12
1.563P STD
------ STD
14
13
1.563P STD
------ STD
15
14
1.563P STD
------ STD
16
15
1.563P STD
------ STD
16
PRE ALARM REC
(0S )
SHUTTLE<<:BACK
<ESTD REC>
D
H
<TIMER PROGRAM>
DW
START END
MODE
>>1 SPL
00:00•00:00 A
2 MON
00:00 05:00 OVER-E OFF
3 ---
--:-- --:-- ----
4 ---
--:-- --:-- ----
5 ---
--:-- --:-- ----
6 ---
--:-- --:-- ----
7 ---
--:-- --:-- ----
8 ---
--:-- --:-- ----
SPL
MON-FRI
see page 48 ).
A-GRADE
A-GRADE
S
M
see pages
P1
MD
OFF
-
-
-
-
-
-