<RECORD SETTINGS>
Settings concerning normal recording and
alarm recording
This unit allows independent settings for normal recording
and alarm recording. By this, more detailed settings are
possible such as changing the recording intervals of the
camera inputting the alarm signals while maintaining the
normal recording settings as they are.
Certain settings and mode changes are limited
during Alarm recording. Pressing the ALARM INTER-
RUPT button halts additional alarm inputs, and lifts
the limitations by stopping recording.
During recording, the setting in the <RECORD
SETTING> screen cannot be changed.
When the cameras for recording are not input
video signal, warning display of "NO SIGNAL" ap-
pears (for details,
OUT output" pages 92, 93).
Recording mode settings for normal
recording and alarm recording
Setting of the camera number for normal recording and alarm
recording, the TRIGGER for alarm recording, the recording inter-
vals and recording picture quality for normal recording and alarm
recording and whether to perform pre-alarm recording for alarm
recording can be set here (for normal recording,
manual recording" pages 23, 24). Pre-alarm recording is a func-
tion to start recording before the ALARM IN terminal on the rear
of the unit is grounded or motion is detected (for details concern-
ing pre-alarm recording,
<RECORD SETTINGS>
>>ALARM SETTING
RECORD SETTING
ALARM REC DURATION
MOTION DET REC
ARCHIVE OVERWRITE
ARCHIVE MEDIA AUTO EJECT
1. Press the SET UP button } <SETTINGS> } Select "ALARM
SETTING" in the <RECORD SETTINGS> screen and turn the
SHUTTLE ring clockwise.
• The <ALARM SETTING> screen appears.
<ALARM SETTING> 1/2
Camera selection during alarm recording
<ALARM SETTING>
ALARM
>>1
2
3
4
5
6
7
8
9
NEXT PAGE
<ALARM SETTING> 2/2
<ALARM SETTING>
ALARM
>>10
11
12
13
14
15
16
EMR
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• Operations
see "Warnings and CALL
see page 68).
5S
ALARM
OFF
OFF
ALARM CH
RECORD CAMERA
TRIGGER
1
--------------- EXT
2
- -------------- EXT
3
-- ------------- EXT
4
--- ------------ EXT
5
---- ----------- EXT
6
----- ---------- EXT
7
------ --------- EXT
8
------- -------- EXT
9
-------- ------- EXT
SHUTTLE<<:BACK
ALARM CH
RECORD CAMERA
TRIGGER
--------- ------ EXT
10 10
---------- ----- EXT
11 11
12 12
----------- ---- EXT
13
------------ --- EXT
14 14
------------- -- EXT
-------------- - EXT
15 15
---------------
16 16
EXT
1
2 3
4 5 6
8
9
7
10 10 11 11
12 12
13 14 14 15 15 16 16
SHUTTLE<<:BACK
The <ALARM SETTING> screen consists of 2
pages. The second page is appeared when turning
the JOG dial to move the cursor to "NEXT PAGE",
and turn the SHUTTLE ring clockwise.
When turn the JOG dial counterclockwise, the cam-
era number setting or the TRIGGER setting will re-
verses in color in order such as
2. Turn the JOG dial and move the cursor to camera selection
item for alarm recording and turn the SHUTTLE ring clockwise.
• The background of setting turns red and flashes.
• Setting ( default : "ALARM CH" )
"ALARM CH" : Alarm recording is performed for only the cameras
set for alarm recording and inputted with alarm signals. When
there is input of alarm signals from multiple cameras, alarm
recording is performed for all cameras containing alarm signals.
"ALARM PLUS" : Recording is performed in the frame speed
set in "A-PPS" for the camera inputted with alarm signals
during normal recording. All other cameras will be recording
in the normal frame intervals.
"ALARM25" : Recording is performed so that normal
recording and alarm recording each are up to max. 25 frames.
With playback of a recording where an alarm recording has
occurred during normal recording, there will be no recording
interval display.
3. Display the desired item to set and turn the SHUTTLE ring
clockwise.
• The setting is confirmed and flashing stops.
see "Basic
4. (When setting the alarm recording camera and trigger • • • )
Turn the JOG dial to select the desired alarm camera channel
number and turn the SHUTTLE ring clockwise.
• The first item from the left side in the "ALARM RECORD
CAMERA" setting display reverses in color.
• The camera numbers are lined in order of the number from
"
" to "
". Multiple camera numbers can be selected for
1
16
one alarm camera channel number.
5. Turn the JOG dial to display the desired camera number
reversed in color and turn the SHUTTLE ring clockwise.
• The background of setting turns red and flashes.
While the setting is flashing, the setting screen can-
not be exited even when pressing the SET UP button.
6. Turn the JOG dial to display the desired setting and turn the
SHUTTLE ring clockwise.
• The setting is confirmed and flashing stops.
7. Turn the JOG dial clockwise to display "TRIGGER" setting
reversed in color and turn the SHUTTLE ring clockwise.
• The background of setting turns red and flashes.
8. Turn the JOG dial to display the desired setting and turn the
SHUTTLE ring clockwise.
• The setting is confirmed and flashing stops.
• Setting of "TRIGGER" ( default : "EXT" )
"EXT" : Alarm recording can only be started when the ALARM
IN terminal is grounded.
"MD&EXT" : Alarm recording can be started when the ALARM
IN terminal is grounded and the motion is detected
simultaneously.
"MD/EXT" : When the ALARM IN terminal is grounded or
motion is detected alarm recording is started.
"MD" : Alarm recording can only be started when the motion
is detected.