1. Fault/UID LED
(amber/blue)
Off
Amber, flashing regularly (1
Hz)
Off
Steadily amber
Amber, flashing regularly (1
Hz)
Off
44
Storage system components
2. Online/activity LED
(green)
Flashing regularly (1 Hz)
Flashing irregularly
Flashing irregularly
Off
Off
Off
Status
drive. To minimize the risk of data loss, do not
replace the drive until the expansion or migration is
complete.
Do not remove the drive. Removing a drive may
terminate the current operation and cause data loss.
The drive is rebuilding, or it is part of an array that
is undergoing capacity expansion or stripe
migration.
The drive is active, but a predictive failure alert has
been received for this drive. Replace the drive as
soon as possible.
The drive is active, and it is operating normally.
A critical fault condition has been identified for this
drive, and the controller has placed it offline.
Replace the drive as soon as possible.
A predictive failure alert has been received for this
drive. Replace the drive as soon as possible.
The drive is offline, a spare, or not configured as
part of an array.