Power Consumption And Cooling - HP Integrity rx2800 i4 User Manual

Hp integrity server
Hide thumbs Also See for Integrity rx2800 i4:
Table of Contents

Advertisement

Table 4 System power specifications (continued)
If an overload triggers the power supply overload protection, the system is immediately powered
off. To reset the power supply unit:
1.
Disconnect the power cord.
2.
Determine what caused the overload by contacting an HP support representative.
3.
Reconnect the power cord.
4.
Reboot the system.
NOTE:
If an overload occurs twice, an undetected short circuit exists.
When you use the front panel power button to turn off the server, power consumption falls below
the low power consumption, but does not reach zero. To reach zero power consumption in "off"
mode, disconnect all power supplies from their power sources.

Power consumption and cooling

The power consumptions listed in
use the HP Power Advisor tool to obtain power information for other configurations or utilization
factors.
Table 5 Standard configuration power consumption
One 1.46 GHz quad-core processor, 4 GB memory,
one 1200 W power supply, and one SAS disk drive
HP Confidential
Parameter
Table 5 (page 15)
Standard configuration
+12VSB /2.5A MAX
+12VSB /2.5A MAX
are valid for the configuration shown. Please
360 W (maximum)
+12VSB /2.5A MAX
Power consumption
1228 Btu/h (maximum)
Server electrical specifications
15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Integrity rx2800 i4Integrity rx2900 i4

Table of Contents