System Specifications
Electrical Specifications
Maximum input current is the worst case or highest current given the lowest input voltage and the maximum
input power.
Table 1-4
System Power Specifications
Parameter
Input voltage
Input current (max)
Input frequency
Measured input power
Available power (output)
Max current at +12V
Max current at –12V
Max current at +3.3V
Max current at +5V
Max current at +3.3V
standby
If an overload triggers the power supply overload protection, the system is immediately powered off. To reset
the power supply unit perform the following steps:
1. Disconnect the power cord.
2. Determine what caused the overload by contacting a HP support representative.
3. Reconnect the power cord, then reboot the system.
If an overload occurs twice, there is an undetected short circuit somewhere.
When you use the front panel's power button to turn off the workstation, power consumption falls below the
low power consumption, but doesn't reach zero. To reach zero power consumption in "off " mode, either unplug
the workstation or use a power block with a switch.

Power Consumption and Cooling

Power consumption for a typical server is 600W/2050 Btu/h. The power consumptions listed in the following
table are valid for a standard configuration as shipped (one 1 GHz processor, 6 GB of memory, 650W power
supply, three hard disk drives, one graphics card, one LVD SCSI card).
All information in this section is based on primary power consumptions.
Table 1-5
Additional Component Power Consumption
Additional Component
Processor
SCSI hard disk drive (with I/O access)
16
Total Rating
100 – 240 VAC
Off
7.2A at 115 VAC or
Off
3.6A at 220 VAC
50 to 60 Hz
Off
560W
Off
650W
Off
49A
0.5A
0.35A
Off
34A
Off
18A
31A
3.5A
Off
130W
23W
Peak
Max. per PCI-X Sockets
(15 sec)
Off
Off
Off
Off
85W total for PCI sockets
Off
0.1A
4.6A
3A
Off
Power Consumption
443.6 Btu/h
78.4 Btu/h
64-bit, 133 MHz