I/O Subsystem; Raid Support - HP Integrity rx2800 i4 User Manual

Hp integrity server
Hide thumbs Also See for Integrity rx2800 i4:
Table of Contents

Advertisement

Figure 3 Internal USB location

I/O subsystem

The I/O subsystem consists of the core I/O and two optional I/O riser boards. Wake-on-LAN is
not enabled on any PCIe Public slots. The server does not support PCI Hot Plug (PHP).
The standard I/O Riser supports one full-height, full-length PCIe x8 and two full-height, half-length
PCIe x4 add-in cards. The second riser option supports one full-height, full-length PCIe x8, and one
full-height, half-length PCIe x8 add-in cards.
NOTE:
All PCIe x8 slots are electrically connected as x8 slots but are physically loaded with x16
connectors.
The secondary I/O riser position can either be a riser that supports one full-height, full-length PCIe
x8 and two low-profile PCIe x4 add-in cards or a riser that supports one full-height, full-length PCIe
x8 and one low profile PCIe x8.

RAID support

The following levels of RAID support are offered:
Zero memory
RAID 0, 1, 10
Maximum 8 drives, 2 logical volumes
No cache or super capacitor needed. Performance improved with cache.
Full feature
RAID 0, 10, 5
Cache needed and installing it automatically enables the full feature firmware stack.
Super capacitor is optional.
Advanced pack
RAID 6, 50, 60
Cache needed. Advanced Pack license must be entered to enable. Super capacitor is
required.
HP Confidential