Gas Supply & Connections; Refractory Panel Installation - HearthStone 8120 Owner's Manual And Installation Manual

Gas-fired, direct-vent heater
Hide thumbs Also See for 8120:
Table of Contents

Advertisement

Hearthstone Quality Home Heating Products, Inc.
G
S
AS
UPPLY
C
ONNECTIONS
NOTICE:
A
qualified
connect the heater to the gas supply and
leak test the unit before it is approved for
use. Consult all codes.
WARNING: The unit must be installed and
connected in accordance with local codes, or in
the absence of local codes, with the most
current edition of the National Fuel Gas Code
ANSI Z223.1 (NFPA 54) or CAN/CGA B149
Installation Code.
NFPA Code, and Hearthstone require the use of
a dedicated sediment trap just upstream of the
unit. Damage to the valve, or other components
due to the lack of a sediment trap are not
covered by warranty.
G as S upply
To E quipm ent
Inlet
N ipple
C ap
Figure 11 Typical Sediment Trap (Required in all
installations)
G
C
AS
ONNECTIONS
The gas supply connection is made to the Tudor's
gas control valve in the middle of the lower rear of
the stove, using a 3/8" male NPT fitting. The supply
line should be ½" diameter, or appropriately sized to
provide a sufficient gas supply to meet the
maximum demand of the unit without undue loss of
pressure. We recommend a flexible line to avoid
undue mechanical load on the valve and to ease
thread alignment, but refer to local codes.
&
technician
must
Inlet
Tee Fitting
3" M IN .
CAUTION: Check Gas Type!
G
S
AS
UPPLY
This appliance and its individual shutoff valve must
be disconnected from the gas supply piping system
during any pressure testing of that system at test
pressures in excess of ½ psig. The Tudor must be
isolated from the gas supply piping system by
closing its individual manual shutoff valve during any
pressure testing of the gas supply piping system at
test pressures equal to or greater than ½ psig.
G
P
AS
RESSURE
NOTE: A QUALIFIED TECHNICIAN
MUST PERFORM THIS PROCEDURE!
Once connected to the gas supply, the supply line
and manifold gas pressures must be tested. The
supply line pressure is tested, to insure it meets the
minimum gas supply pressure as listed in the
Specifications for the type of fuel in use (natural gas
or LP), by connecting a manometer to the supply
line
and
adjusting
necessary to meet the required supply line pressure
as listed in specifications. The manifold pressure tap
on the gas control valve, refer to
location.
R
EFRACTORY
I
NSTALLATION
CAUTION: Fragile!
Always wear gloves and safety goggles while
handling.
Only the panel set supplied with the Tudor should
be placed in the firebox. Do not place any other
materials in the firebox. If the panel set is damaged
or broken contact your dealer for replacement. It
must
be
replaced
replacement parts.
combustion quality and safety of the heater. The
panel set will last a long time; however, they will
break if subjected to rough or improper handling.
Exact positioning of the panel set is required in
order to obtain a pleasing flame pattern and efficient
combustion. Incorrect placement may cause carbon
build-up; excess thermal stress on the panels and
stove parts, reduced efficiency, and high levels of
18
TUDOR 8120 Gas-Fired Direct-Vent
A
DJUSTMENT
the
incoming
pressure
Figure 10
P
ANEL
Handle panel set with care.
with
the
same
approved
These components affect the
if
for

Advertisement

Table of Contents
loading

Table of Contents