Hearthstone Quality Home Heating Products, Inc.
V
C
ENTING
OMPONENTS
C
ONFIGURATION
The Tudor cannot be vented jointly with any other
solid fuel or gas appliance. It must be vented
directly to the outside of the building using a proper
termination as listed in the manual. The only types
of venting pipe approved for use with your Tudor
Direct-Vent stove is Simpson Dura-Vent's GS,
AmeriVent Direct, Selkirk Direct Temp™ and Secure
Vent Direct-Vent Pipe. The venting configuration is
Figure 6
shown in
. After determining the venting
configuration for your stove, select the vent system
that will accommodate your installation.
Caution: Be sure there is no wiring or
plumbing in the chosen location.
Caution: Venting terminals shall not be
recessed into a wall or siding.
Note: If further direction is needed for installation,
please refer to the venting instructions, which are
provided with the venting components.
Acceptable Direct-Vent
Termination Cap Locations
The vent/air intake termination clearances above the
high side of an angled roof are as follows:
Roof Pitch
Feet
Flat to 6/12
1
7/12 to 9/12
2
10/12 to 12/12
4
13/12 to 16/12
6
17/12 to 21/12
8
Listed are Simpson Dura-Vent, AmeriVent Direct,
Selkirk
Direct
Temp™
components acceptable for installation, along with
the minimum venting kit available. The venting
system must be comprised of the appropriate
venting components as specified.
A
V
PPROVED
ENTING
C
OMPONENTS
(The following are components that are available,
but not necessary for all installations)
0
90
Elbow
0
45
Elbow
6" Straight
9" Straight (Simpson only)
&
Meters
0.3
0.6
1.2
1.8
2.4
and
Secure
Vent
S
YSTEM
12" Straight
24" Straight
36" Straight
48" Straight
11"-14 5/8" Adjustable Pipe Length
Horizontal Vent Cap
Vertical Vent Cap
14" Snorkel
Vinyl Siding Standoff 4 x 6 5/8"
Round Ceiling Support Wall
Thimble Covers
Wall thimble
Wall Pass Through Insulation Blanket
wherever a wall pass through is installed)
C
L
HIMNEY
INER
1. Direct-Vent Chimney Liner Termination Kit
2. Chimney Liner Flex
3. Co-Linear Flex Connector
4. Co-Axial to Co-Linear Appliance Connect
(Masonry approved, not to exceed 16')
M
V
INIMUM
ENT
6" Straight
Wall Thimble Cover (optional)
Wall Thimble
Horizontal Vent Cap
Wall thimble Insulation Blanket
HearthStone)
13
Tudor Model #8120
(Required
S
YSTEM
K
IT
(Supplied by