Generators:
If a generator must be used, it must be the minimum size listed below or greater.
The generator must have a 30A circuit and capable of providing a minimum of
wattage at the required voltage. Under size generators will cause motor damage
and is not covered under warranty.
Motor HP
5 HP 230v
5 HP 230-460v 3 Phase
7-1/2 HP 230-460v 3 Phase
5 HP 600v 3 Phase
7-1/2 HP 575v 3 Phase
I. PREPARATION
F. Wiring Diagram
Model
Part#
BBL527
BBL547
232088
BBL5247
BBL527 3PHASE
BBL547 3PHASE
232099
BBL5247 3PHASE
BBL727 3PHASE
232100
BBL7247 3PHASE
BBL727 575v
232157
3PHASE
BBL527 600v
23215
3PHASE
Before attempting any electrical work always verify the voltage, phase, and Baldor
Motor Specification from the Motor Name Plate with the Chart Shown Above. Any
failure due to misapplication of voltages and or Phase is not covered under any
warranty.
For any Electric Motor service, warranty, or technical related questions contact your nearest
Baldor service center:
Baldor Electric Company
Corporate Headquarters
5711 R.S. Boreham, Jr. St.
P.O. Box 2400
Fort Smith, AR 72901
Phone: (501) 646-4711
Fax: (501) 648-5792
Web: http://www.baldor.com
UPC#
Description
00510003898
MOT 5.0HP 230v/60/1 W/Switch
70184683437
MOT 5HP 230-460/60/3 W/Switch
70184683438
MOT 7.5HP 230-460/60/3
W/Switch
70184627209
MOT 7.5HP 575/60/3 W/Switch
70184626967
MOT 5HP 600/60/3 W/Switch
No Thermal Overload Protector
10
Minimum Generator Size
17.6 Kw
15.2 Kw
22.6 Kw
15.2 Kw
22.6 Kw
HPVolts Hz PH
5 230v 60 1
230-
5
460v 60 3
7.5230-
460v
7.5575v 60 3
5 600v 60 3
Baldor
Specification
36J656Y959
36H968W189G1
60 3
36K167T227
36N332S715
CD0003A02
CD0383A02
36H968T894
Baldor
Drawing
CD1122
CD1597
CD1597