Left or Right Side Venting
Venting Behind Cabinet Kickplate
m
00
r'_
/
B
A. Wall cap
B. 6" (15.2 cm) round roof venting
--A
Concrete Slab Installations - Exhaust Through Wall
B
A
L
iiii!iiii!iii!
.......
di
/
D
H
A. Wall cap
B. 6" (15.2 cm) round metal vent
C. 16" (40.6 cm) maximum
D. 6" (15.2 cm) round PVC sewer pipe
E. Concrete slab
F. 6" (15.2 cm) round PVC sewer pipe
G. 6" (15.2 cm) round 90 ° PVC sewer pipe elbow
H. Tightly pack gravel or sand completely
around pipe.
1.30ft(9.1
m) max.
J. 6" (15.2 cm) round 90 ° PVC sewer pipe elbow
K. 6" (15.2 cm) round PVC coupling
L. 12" (30.5 cm) minimum
Concrete Slab Installations -
Exhaust Through Window Well
IMPORTANT: Window well installation for electric models only.
B
D
A!
/n C
.....
........
F
n
_
I_ _
M----_t
.............
G
J
IMPORTANT: This range is rated at 60 ff (18.3 m) of straight duct.
Low range is up to 30 ft (9.1 m); high range is 31 ff (9.4 m) to
60 ft (18.3 m).
If equivalent duct length exceeds 30 ft (18.3 m), the blower must
be converted to high range.
Do not convert to high range for shorter lengths. This will
cause excessive noise, conditioned
air loss and affect the
flame pattern on gas ranges.
To convert blower for high range installations, see the
"Install Downdraft
System" section.
To calculate the length of the system you need, add the
equivalent feet (meters) for each vent piece used in the system.
Vent Piece
6" (15.2 cm) Round
45 ° elbow
2.5 ft
(0.8 m)
90 ° elbow
5.0 ft
(1.5 m)
6" (15.2 cm)
0.0 ft
wall cap
(0.0 m)
3V4" x 10" (8.3 cm x 25.4 cm)
4.5 ft
to 6" (15.2 cm) transition
(1.4 m)
6" (15.2 cm) to 3V4" x 10"
1 ft
(8.3 cm x 25.4 cm) transition
(0.3 m)
3V4" x 10" (8.3 cm x 25.4 cm)
5.0 ft
to 6" (15.2 cm) 90 ° elbow
(1.5 m)
transition
6" (15.2 cm) to 3V4" x 10"
5.0ft
(8.3 cm x 25.4 cm) 90 ° elbow
(1.5 m)
transition
3V4" x 10" (8.3 cm x 25.4 cm)
5.0 ft
90 ° elbow
(1.5 m)
A. Wall cap
B. 12" (30.5 cm) minimum
C. Concrete slab
D. 6" (15.2 cm) round PVC sewer pipe
E. 6" (15.2 cm) round PVC sewer pipe
F. 6" (15.2 cm) round 90 ° PVC sewer pipe elbow
G. Tightly pack gravel or sand completely
around pipe.
H. 42 ft (12.8 m) max.
I. 6" (15.2 cm) round PVC coupling
J. 6" (15.2 cm) minimum
K. Window well
3V4" x 10" (8.3 cm x 25.4 cm)
12.0 ft
flat elbow
(3.7 m)
3V4" x 10" (8.3 cm x 25.4 cm)
0.0 ft
wall cap
(0.0 m)