Jenn-Air JES9750CAB00 Installation Instructions Manual page 14

Electric downdraft slide-in ranges
Hide thumbs Also See for JES9750CAB00:
Table of Contents

Advertisement

Available languages

Available languages

Power Supply Cord
Direct Wire
Electrical Shock Hazard
Disconnect power before servicing.
Use a new 40 amp power supply cord.
Plug into a grounded outlet.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Electrical Shock Hazard
Disconnect power before servicing.
Use 8 gauge copper or 6 gauge aluminum
wire.
Electrically ground range.
Failure to follow these instructions can result in death,
fire, or electrical shock.
1=
2.
3.
Disconnect
power.
Use Phillips screwdriver to remove the terminal block cover
screw located on the back of the range. Pull cover down and
toward you to remove cover.
Remove plastic tag holding three 10-32 hex nuts from the
middle post of the terminal block.
4. Add strain relief.
Style 1: Power supply cord strain relief
Assemble a UL listed strain relief in the opening.
A
A. UL listed strain relief
Feed the power supply cord through the opening in the
cord/conduit
plate on bottom of range. Allow enough
slack to easily attach the wiring to the terminal block.
Tighten strain relief screw against the power supply cord.
14

Advertisement

Table of Contents
loading

Table of Contents