Disconnect and reconnect the Switch's power to begin a session. When you
2
reconnect the Switch's power, you will see the initial screen.
When you see the message "Press any key to enter Debug Mode within 3
3
seconds ..." press any key to enter debug mode.
Type atlc after the "Enter Debug Mode" message.
4
Wait for the "Starting XMODEM upload" message before activating XMODEM
5
upload on your terminal.
After a configuration file upload, type atgo to restart the Switch.
6
Figure 20 Resetting the Switch: Via the Console Port
Bootbase Version: V1.05 | 07/29/2008 09:42:05
RAM: Size = 65536 Kbytes
DRAM POST: Testing: 65536K
OK
FLASH: AMD 128M *1
CACHE_WB
ZyNOS Version: V3.90(BBD.0)b1 | 07/29/2008 09:44:04
Press any key to enter debug mode within 3 seconds.
ras> atlc
Starting XMODEM upload (CRC mode)....
CCCCCCCCCCCCCCCC
Total
393216 bytes received.
Erasing..
................................................................
OK
ras> atgo
The Switch is now reinitialized with a default configuration file including the default
password of "1234".
MES-3728 User's Guide