Table 103 SNMP System Traps (continued)
OPTION
OBJECT LABEL
intrusionlo
IntrusionLockEventOn
ck
loopguard
LoopguardEventOn
externalar
ExternalAlarmEventOn
m
ExternalAlarmEventClear
Table 104 SNMP Interface Traps
OPTION
OBJECT LABEL
linkup
linkUp
LinkDownEventClear
linkdown
linkDown
LinkDownEventOn
autonegotiati
AutonegotiationFailedEve
on
ntOn
AutonegotiationFailedEve
ntClear
lldp
LLDPRemoteTopologyCha
nge
transceiver-
transceiverddmiEventOn
ddmi
transceiverddmiEventClea
r
MES-3728 User's Guide
OBJECT ID
1.3.6.1.4.1.890.1.5.8.45.2
7.2.1
1.3.6.1.4.1.890.1.5.8.45.2
7.2.2
1.3.6.1.4.1.890.1.5.8.45.2
7.2.1
1.3.6.1.4.1.890.1.5.8.45.2
7.2.2
OBJECT ID
1.3.6.1.6.3.1.1.5.4
1.3.6.1.4.1.890.1.5.8.45.27
.2.2
1.3.6.1.6.3.1.1.5.3
1.3.6.1.4.1.890.1.5.8.45.27
.2.1
1.3.6.1.4.1.890.1.5.8.45.27
.2.1
1.3.6.1.4.1.890.1.5.8.45.27
.2.2
1.0.8802.1.1.2.0.0.1
1.3.6.1.4.1.890.1.5.8.45.27
.2.1
1.3.6.1.4.1.890.1.5.8.45.27
.2.2
Chapter 34 Access Control
DESCRIPTION
This trap is sent when intrusion
lock occurs on a port.
This trap is sent when
loopguard shuts down a port.
This trap is sent when the
external alarm is received.
This trap is sent when the
external alarm stops sending
an alert.
DESCRIPTION
This trap is sent when the
Ethernet link is up.
This trap is sent when the
Ethernet link is up.
This trap is sent when the
Ethernet link is down.
This trap is sent when the
Ethernet link is down.
This trap is sent when an
Ethernet interface fails to
auto-negotiate with the
peer Ethernet interface.
This trap is sent when an
Ethernet interface auto-
negotiates with the peer
Ethernet interface.
This trap is sent when the
LLDP (Link Layer Discovery
Protocol) remote topology
changes.
This trap is sent when one
of the device operating
parameters (such as
transceiver temperature,
laser bias current,
transmitted optical power,
received optical power and
transceiver supply voltage)
is above or below a factory
set normal range.
This trap is sent when all
device operating
parameters return to the
normal operating range.